Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342306289 | 0418300 | 2017-05-02 | 1274 CHURCH AVENUE, RAINSVILLE, AL, 35986 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1205556 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100212 A03 II |
Issuance Date | 2017-09-20 |
Abatement Due Date | 2017-10-02 |
Current Penalty | 6463.8 |
Initial Penalty | 9234.0 |
Final Order | 2017-09-29 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: (a) On or about 04/25/2017 - Press & Trim Department, Pacific 90 Ton Trim Press Brake, Model J135-21H, Serial #9401, employees breaking material to form an approximately 3/8 inch hem were exposed to amputation injuries at the point of operation. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100212 A03 III |
Issuance Date | 2017-09-20 |
Abatement Due Date | 2017-10-02 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2017-09-29 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(3)(iii): Special hand tools for placing and removing material(s) was not provided to permit easy handling of material without the operator placing a hand in the danger zone: (a) On or about 04/25/2017 - Press & Trim Department, Pacific 90 Ton Trim Press Brake, Model J135-21H, Serial #9401, special hand tools were not provided to prevent operators from coming in contact with the point of operation. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2010-10-28 |
Emphasis | N: SSTARG09 |
Case Closed | 2010-12-03 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2010-10-28 |
Abatement Due Date | 2010-11-05 |
Current Penalty | 4900.0 |
Initial Penalty | 7000.0 |
Nr Instances | 4 |
Nr Exposed | 4 |
Gravity | 10 |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100303 B07 I |
Issuance Date | 2010-10-28 |
Abatement Due Date | 2010-11-05 |
Current Penalty | 2800.0 |
Initial Penalty | 4000.0 |
Nr Instances | 2 |
Nr Exposed | 3 |
Gravity | 05 |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100304 G05 |
Issuance Date | 2010-10-28 |
Abatement Due Date | 2010-11-05 |
Current Penalty | 2800.0 |
Initial Penalty | 4000.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 05 |