Events

Event Date Event Type Old Value New Value
2008-01-02 Name Change ZCC Corporation Zachry Construction Corporation

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340047760 0418600 2014-10-29 1007 N 6TH AVE, LANETT, AL, 36863
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2014-10-29
Emphasis L: FALL, P: FALL
Case Closed 2015-01-05

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B05 II
Issuance Date 2014-11-14
Abatement Due Date 2014-11-26
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-12-04
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end. a) Northwest corner of scaffolding on the west wall; on or about October 29, 2014 and times prior the employer did not ensure that planking of the work platform 19.7 feet above the ground did not extend over its support more than 18 inches.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02 I
Issuance Date 2014-11-14
Abatement Due Date 2014-11-26
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-12-04
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement: a) Base of scaffolding on the west wall; on or about October 29, 2014 and times prior the employer did not ensure that the footing of the work platform 19.7 feet above the ground had a baseplate and was placed on a stable footing.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2014-11-14
Abatement Due Date 2014-11-26
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-12-04
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Entire site; on or about October 29, 2014 and times prior the employer did not ensure that an access ladder was available to access the work platform 19.7 feet above the ground
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2014-11-14
Abatement Due Date 2014-11-26
Current Penalty 1200.0
Initial Penalty 2000.0
Final Order 2014-12-04
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Scaffold on west wall; on or about October 29, 2014 and times prior the employer did not ensure that employees were provided fall protection while working on a work platform 19.7 feet above the ground.
312932890 0418600 2009-03-25 152 BRICK PLANT ROAD, ALEXANDER CITY, AL, 35011
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2009-03-26
Case Closed 2009-04-24

Related Activity

Type Complaint
Activity Nr 206975062
Safety Yes
Type Complaint
Activity Nr 206973083
Safety Yes
Health Yes
305123457 0418600 2003-03-04 152 BRICK PLANT ROAD, ALEXANDER CITY, AL, 35011
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2003-03-05
Emphasis S: CONSTRUCTION
Case Closed 2003-03-07
302616826 0418600 2000-02-01 INDUSTRIAL ROAD (NUTRA-SWEET PLANT), MCINTOSH, AL, 36653
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2000-02-01
Emphasis S: CONSTRUCTION
Case Closed 2000-02-16

Related Activity

Type Complaint
Activity Nr 200452332
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19260025 A
Issuance Date 2000-02-16
Abatement Due Date 2000-02-22
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 01
302616792 0418600 2000-01-20 OLIN INDUSTRIAL ROAD. BOX M, MCINTOSH, AL, 36553
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2000-01-20
Emphasis S: CONSTRUCTION
Case Closed 2000-02-04

Related Activity

Type Accident
Activity Nr 100451038
Type Complaint
Activity Nr 200452233
Safety Yes