346481872
|
0418300
|
2023-01-30
|
931 2ND AVENUE SOUTHEAST, FAYETTE, AL, 35555
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2023-07-21
|
Case Closed |
2023-07-25
|
Related Activity
Type |
Complaint |
Activity Nr |
1991389 |
Safety |
Yes |
Health |
Yes |
|
|
344619887
|
0418300
|
2020-02-10
|
931 2ND AVENUE SE, FAYETTE, AL, 35555
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2020-06-05
|
Case Closed |
2020-07-20
|
Related Activity
Type |
Complaint |
Activity Nr |
1540575 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100120 Q02 |
Issuance Date |
2020-06-08 |
Abatement Due Date |
2020-07-24 |
Current Penalty |
4915.8 |
Initial Penalty |
8193.0 |
Final Order |
2020-06-16 |
Nr Instances |
1 |
Nr Exposed |
185 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.120(q)(2): The employer did not develop an emergency response plan for emergencies which addressed the following minimum requirements of this standard: 1910.120(q)(2)(i) through 1910.120(q)(2)(xii): (a) On or about February 10, 2020 - Facility, the employer had not developed and implemented a written plan in the event of an emergency such as, but not limited to, a Chlorine release. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100120 Q06 II |
Issuance Date |
2020-06-08 |
Abatement Due Date |
2020-07-24 |
Current Penalty |
4915.8 |
Initial Penalty |
8193.0 |
Final Order |
2020-06-16 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.120(q)(6)(ii): First responders at the operational level did not receive at least eight hours of training or did not have sufficient experience to objectively demonstrate competency in the areas required by 29 CFR 1910.120(q)(6)(ii)(A) through (q)(6)(ii)(F) and/or the employer did not so certify: (a) On or about February 10, 2020 - Facility, the employer had not ensured that training was provided to employees expected to initially respond to a hazardous substance release such as, but not limited to, Chlorine gas. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100120 Q06 III |
Issuance Date |
2020-06-08 |
Abatement Due Date |
2020-07-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-16 |
Nr Instances |
1 |
Nr Exposed |
30 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.120(q)(6)(iii): Employees who participated as hazardous materials technicians, or were expected to participate as hazardous materials technicians, had not received at least 24 hours of training equal to the first responder operations level, and in addition have competency in the areas outlined in 29 CFR 1910.120(q)(6)(iii)(A) through (q)(6)(iii)(I) and/or the employer did not so certify: (a) On or about February 10, 2020 - Facility, the employer had not ensured that training was provided to employees expected to respond and stop a hazardous substance release such as, but not limited to, Chlorine gas. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2020-06-08 |
Abatement Due Date |
2020-07-02 |
Current Penalty |
4915.8 |
Initial Penalty |
8193.0 |
Final Order |
2020-06-16 |
Nr Instances |
1 |
Nr Exposed |
185 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On or about February 10, 2020 - Facility, employees had not been provided effective information and training regarding the hazards associated with Chlorine. |
|
|
343678801
|
0418300
|
2018-12-21
|
931 2ND AVE SE, FAYETTE, AL, 35555
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-12-21
|
Case Closed |
2019-03-06
|
Related Activity
Type |
Referral |
Activity Nr |
1411209 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2018-12-31 |
Current Penalty |
7853.0 |
Initial Penalty |
7853.0 |
Final Order |
2019-01-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer failed to report the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, within (24) twenty-four hours: a) On or about December 21, 2018 - Line 7, an employee sustained a fractured left leg while working on 12/15/2018. |
|
|
341069516
|
0418300
|
2015-11-19
|
931 2ND AVE SE, FAYETTE, AL, 35555
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-12-03
|
Case Closed |
2016-04-29
|
Related Activity
Type |
Complaint |
Activity Nr |
1038330 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100023 C03 |
Issuance Date |
2016-04-06 |
Abatement Due Date |
2016-05-02 |
Current Penalty |
1530.0 |
Initial Penalty |
2550.0 |
Final Order |
2016-04-18 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing: (a) On or about 11/19/15 - Production areas, the intermediate rail was missing from the guardrail system(s) installed around the pit that contained the Form stripping equipment at production line #6. (b) On or about 11/19/15 - Production areas, the intermediate rail was missing from the guardrail system(s) installed around the pit that contained the Form stripping equipment at production line #8. c) On or about 11/19/15 - Production areas, the intermediate rail was missing from the guardrail system(s) installed around the pit that contained the Form stripping equipment at production line #9. d) On or about 11/19/15 - Production areas, the intermediate rail was missing from the guardrail system(s) installed around the pit that contained the Form stripping equipment at production line #10. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100023 D01 |
Issuance Date |
2016-04-06 |
Abatement Due Date |
2016-05-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-04-18 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers shall be equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section: (a) On or about 11/19/15 - Potassium Hydroxide tank, the standard rails installed on both sides of the stairs were missing the intermediate rail. (b) On or about 11/19/15 - Compounding mix tanks, the standard rails installed on both sides of the stairs were missing the intermediate rail. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100101 C |
Issuance Date |
2016-04-06 |
Abatement Due Date |
2016-05-02 |
Current Penalty |
3060.0 |
Initial Penalty |
5100.0 |
Final Order |
2016-04-18 |
Nr Instances |
1 |
Nr Exposed |
10 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.101(c): Compressed gas cylinders, portable tanks, and cargo tanks did not have pressure relief devices installed and maintained in accordance with Compressed Gas Association Pamphlets S-1.1-1963 and 1965 addenda and S-1.2-1963: (a) On or about 11/19/15 - Production Line #5, the pressure relief valve on the Superior Gas Chlorinator was not vented to a safe location. Employees working in the production area were exposed to release of chlorine if venting occurred at the metering valve. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2016-04-06 |
Abatement Due Date |
2016-05-02 |
Current Penalty |
3060.0 |
Initial Penalty |
5100.0 |
Final Order |
2016-04-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) On or about 11/19/15 - Chlorine storage building, suitable facilities were not provided where chlorine cylinders are transported, stored, and handled. |
|
|