Name: | Harco Metal Products, Inc. |
Jurisdiction: | Alabama |
Legal type: | Foreign Corporation |
Status: | Exists |
Date of registration: | 01 Oct 1990 (34 years ago) |
Entity Number: | 000-925-264 |
Register Number: | 000925264 |
ZIP code: | 35978 |
County: | De Kalb |
Place of Formation: | Arizona |
Registered Office Street Address: | 69 INDUSTRIAL PARK DRHENAGAR, AL 35978 |
Principal Address: | 3632 E LASALLE STPHOENIX, AZ 85040 |
Name | Role |
---|---|
KRAMER, JEFF | Agent |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339031205 | 0418300 | 2013-05-01 | 162 JACK COOPER DRIVE, VALLEY HEAD, AL, 35989 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 815176 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100215 A04 |
Issuance Date | 2013-06-05 |
Abatement Due Date | 2013-06-24 |
Current Penalty | 2520.0 |
Initial Penalty | 4200.0 |
Final Order | 2013-06-19 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch: (a) On or about 5/1/2013 - Heil area, the work rests on three (3) DAYTON floor-mounted bench grinders, Model 4Z909C were adjusted at 1/2 inch from the wheel. (b) On or about 5/1/2013 - Heil Area, the work rests on two (2) of three (3) DAYTON floor-mounted bench grinders, Model 4Z909C were missing. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100215 B09 |
Issuance Date | 2013-06-05 |
Abatement Due Date | 2013-06-24 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-06-19 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch: (a) On or about 5/1/2013 - Heil area, the safety guard(s) on three (3) DAYTON floor mounted bench grinders, Models 4Z909C were adjusted to between 1 inch and 2 inches. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19101200 H01 |
Issuance Date | 2013-06-05 |
Abatement Due Date | 2013-08-01 |
Current Penalty | 1260.0 |
Initial Penalty | 2100.0 |
Final Order | 2013-06-19 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On or about 5/1/2013 - Danfoss area, Heil area, and Saw area, employees working with hazardous chemicals including, but not limited to, Mean Green, Fusion Fuze Clean FS, and Doringer H-32 Coolant Concentrate (10:1) had not been trained. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100147 C04 I |
Issuance Date | 2013-06-05 |
Abatement Due Date | 2013-08-01 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-06-19 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about May/1/2013 - Danfoss area, Heil area, Saw area, procedures were not developed and documented for equipment such as, but not limited to, CNC machines located near the Danfoss area, a Leonard Tube Master, Model 3 CPVD, Serial #1222 in the Heil area, and the Doringer Rotating Metal Chop Saw, Model D3540, Serial # 21772 in the Saw area. |
Inspection Type | Complaint |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2008-01-24 |
Case Closed | 2008-06-16 |
Related Activity
Type | Complaint |
Activity Nr | 205690241 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100147 C01 |
Issuance Date | 2008-03-27 |
Abatement Due Date | 2008-04-22 |
Current Penalty | 1125.0 |
Initial Penalty | 1500.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2008-03-27 |
Abatement Due Date | 2008-04-10 |
Current Penalty | 1125.0 |
Initial Penalty | 1500.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100151 C |
Issuance Date | 2008-03-27 |
Abatement Due Date | 2008-04-21 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 01 |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100178 L01 I |
Issuance Date | 2008-03-27 |
Abatement Due Date | 2008-05-13 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 01 |
Date of last update: 16 Aug 2024
Sources: Alabama Secretary of State