Name: | Cherokee Nitrogen Holdings, Inc. |
Jurisdiction: | Alabama |
Legal type: | Foreign Corporation |
Status: | Merged |
Date of registration: | 19 Sep 2000 (24 years ago) |
Entity Number: | 000-918-325 |
Register Number: | 000918325 |
Historical Names: |
Cherokee Nitrogen Company, Inc.
|
ZIP code: | 36104 |
County: | Montgomery |
Place of Formation: | Oklahoma |
Principal Address: | 16 S PENNSYLVANIA AVEOKLAHOMA CITY, OK 73107 |
Registered Office Street Address: | 150 S PERRY STMONTGOMERY, AL 36104 |
Name | Role |
---|---|
CAPITOL CORPORATE SERVICES INC | Agent |
Event Date | Event Type | Old Value | New Value |
---|---|---|---|
2003-12-08 | Name Change | Cherokee Nitrogen Company, Inc. | Cherokee Nitrogen Holdings, Inc. |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
337423214 | 0418300 | 2012-11-14 | 1080 INDUSTRIAL DRIVE, CHEROKEE, AL, 35616 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 661431 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100119 J02 |
Issuance Date | 2013-05-10 |
Current Penalty | 6300.0 |
Initial Penalty | 6300.0 |
Final Order | 2013-06-06 |
Nr Instances | 1 |
Nr Exposed | 8 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.119(j)(2): The employer did not implement written procedures to maintain the on-going integrity of process equipment: (a) On or about 3/7/13 - at the No. 2 Nitric Acid Plant, the written procedure, "Nitric #9 Converter Installation" dated 1/20/86, was not implemented for proper bolt tightening when changing the platinum catalyst gauze at the 212-A converter (top hat) and converter elbow flange. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100119 J04 IV |
Issuance Date | 2013-05-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-06-06 |
Nr Instances | 1 |
Nr Exposed | 8 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.119(j)(4)(iv): The employer did not document each inspection and test that was performed on process equipment: (a) On or about 3/7/13 - at the No. 2 Nitric Acid Plant, documentation was not available for PSV-001 and -002 on the High Pressure Condenser (9-223-C1). (b) On or about 3/7/13 - at the No. 2 Nitric Acid Plant, documentation was not available for PSV-003 and -004 on the Coolant Chiller for Frick (9-223-C2). (c) On or about 3/7/13 - at the No. 2 Nitric Acid Plant, documentation was not available for PSV-005 and -006 on the Coolant Chiller for Frick (9-223-F1). (d) On or about 3/7/13 - at the No. 2 Nitric Acid Plant, documentation was not available for PSV-007 and -008 on the Frick Compressor (9-223-J). |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100147 C06 II |
Issuance Date | 2013-05-10 |
Abatement Due Date | 2013-06-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-06-06 |
Nr Instances | 1 |
Nr Exposed | 9 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) On or about 4/22/13 - at 1080 Industrial Dr., Cherokee, AL, the employer did not certify that periodic inspections had been performed. |
Citation ID | 02003 |
Citaton Type | Other |
Standard Cited | 19100147 D01 |
Issuance Date | 2013-05-10 |
Abatement Due Date | 2013-05-22 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-06-06 |
Nr Instances | 1 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.147(d)(1): The authorized employee did not have knowledge of the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy before the authorized or affected employee turned off the machine or equipment: (a) On or about 11/13/12 - at Urea reactor 1303-D, the isolation package 1303-D (Urea Reactor) procedure #42IP006 dated 1/31/12, that was used in conjunction with a completed line breaking permit, did not inform employees of the magnitude of energy being controlled. |