346426232
|
0418600
|
2023-01-10
|
750A VIADUCT RD, CHICKASAW, AL, 36611
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-01-10
|
Emphasis |
N: CHROME6, L: MARITIME, P: MARITIME
|
Case Closed |
2023-05-17
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100157 C01 |
Issuance Date |
2023-04-07 |
Abatement Due Date |
2023-04-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-05-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(1):The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury: a) Main Warehouse; On or about January 10, 2022, and times prior the employer exposed employees to struck by hazards in that the employer did not ensure fire extinguishers were mounted properly. |
|
|
340671635
|
0418600
|
2015-06-02
|
750A VIADUCT RD, CHICKASAW, AL, 36611
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-06-02
|
Emphasis |
L: FORKLIFT
|
Case Closed |
2015-07-21
|
Related Activity
Type |
Complaint |
Activity Nr |
986979 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A02 |
Issuance Date |
2015-06-17 |
Current Penalty |
1926.0 |
Initial Penalty |
2168.0 |
Final Order |
2015-07-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: At the North end of the Fabrication Shop: On June 2, 2015 and at times prior to; the employer exposed employees working in and around standing rain water to slip hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100184 C06 |
Issuance Date |
2015-06-17 |
Abatement Due Date |
2015-07-07 |
Current Penalty |
1926.0 |
Initial Penalty |
4250.0 |
Final Order |
2015-07-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.184(c)(6): Slings were not securely attached to their loads: (a) In the fabrication shop: On June 6 and at times prior to; the employer allowed employees using and working around a chain sling attached to the spreader bar to be exposed to struck-by and crushing hazards from loads up to 9.8 tons in that the chain sling hooks that were designed for latches were not equipped with hook latches. |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19100184 E01 |
Issuance Date |
2015-06-17 |
Abatement Due Date |
2015-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: (a) In the warehouse: On June 2, 2015 and at times prior to; the employer failed to identify a chain sling. |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19100184 C14 |
Issuance Date |
2015-06-17 |
Abatement Due Date |
2015-07-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.184(c)(14): 29 CFR 1910.184(c)(14): Employers used slings without affixed and legible identification markings: (a) In the Fabrication Shop: On June 2, 2015 and at times prior to; the employer exposed employees using chain slings on the spreader bar, to struck-by and crushing hazards in that the identification tag was not legible by the compliance officer or the safety manager. |
|
|