347364564
|
0418600
|
2024-03-12
|
50 COUNTY CT, MONTGOMERY, AL, 36105
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2024-03-13
|
Emphasis |
L: FORKLIFT, P: AMPUTATE, N: AMPUTATE
|
Case Closed |
2024-09-11
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2024-08-14 |
Abatement Due Date |
2024-08-28 |
Current Penalty |
5171.4 |
Initial Penalty |
8619.0 |
Final Order |
2024-09-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Production Department (Fibrous - Wetting Area): On or about March 12, 2024, and at times prior, the employer exposed employees to laceration hazards in that adequate machine guarding for the pre-sticking and guide rollers were not provided to employees performing wetting activities for production on the SMOK-E Moisturizer No. 1. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040041 A01 I |
Issuance Date |
2024-08-14 |
Current Penalty |
1292.4 |
Initial Penalty |
2154.0 |
Final Order |
2024-09-11 |
Nr Instances |
1 |
Nr Exposed |
140 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.41(a)(1)(i):The establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and the establishment was classified in an industry listed in appendix A to subpart E of this part, and the employer did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee by the specified date: (a) Viscofan USA, Inc., 50 County Ct, Montgomery, AL: On or about March 2, 2024, the employer failed to electronically submit information from their OSHA Form 300A, Summary of Work-Related Injuries and Illnesses or equivalent form, for calendar year 2023 on or before March 2, 2024. The establishment employed 140 employees during calendar year 2023 and was classified under NAICS code 326121 . |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100036 G02 |
Issuance Date |
2024-08-14 |
Abatement Due Date |
2024-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. a) Production Department (Collagen Area): On or about March 12, 2024, and times prior, the employer failed to maintain exit access routes of at least twenty-eight (28) inches in between the Collagen Machines while employees are cleaning, sweeping and maintenance activities. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100157 C01 |
Issuance Date |
2024-08-14 |
Abatement Due Date |
2024-08-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-11 |
Nr Instances |
2 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Quality Control Department (Laboratory): On or about March 12, 2024, and times prior, the employer failed to mount and make readily accessible a portable fire extinguisher in the work area for employees during fire emergency events. b) Warehouse Department (Wrapping Area): On or about March 12, 2024, and times prior, the employer failed to mount and make readily accessible a portable fire extinguisher in the work area for employees during fire emergency events. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100178 A06 |
Issuance Date |
2024-08-14 |
Abatement Due Date |
2024-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place. a) Warehouse Department: (Forklift Operations): On or about March 12, 2024, and at times prior; the employer allowed his employees to operate a Mitsubishi Caterpillar Forklift that was missing the markings on the shift control lever to indicate the use and purpose for the lever. |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19100215 A04 |
Issuance Date |
2024-08-14 |
Abatement Due Date |
2024-08-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a) Maintenance Department (Bench Grinder Area): On or about March 12, 2024, and at times prior; work rests were not provided to employees while performing grinding activities on a DeWalt 8" Bench Grinder. |
|
Citation ID |
02006 |
Citaton Type |
Other |
Standard Cited |
19100215 B09 |
Issuance Date |
2024-08-14 |
Abatement Due Date |
2024-08-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: a) Maintenance Department (Bench Grinder Area): On or about March 12, 2024, and at times prior; employees were performing grinding/buffing activities on a DeWalt 8" Bench Grinder that did not have an adjustable guard. |
|
Citation ID |
02007 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 I B |
Issuance Date |
2024-08-14 |
Abatement Due Date |
2024-08-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-11 |
Nr Instances |
2 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater: a) Production Department (Air Compressor Area): On or about March 12, 2024, and times prior, the employer failed to provide a clear and unobstructed path of at least 762 mm (30 inches) in front of an electrical panel breaker box for employees use during service and maintenance activities. b) Production Department (Collagen Area): On or about March 12, 2024, and times prior, the employer failed to provide a clear and unobstructed path of at least 762 mm (30 inches) in between the Collagen Machines back electrical panels for employees use during service, maintenance and cleaning activities. c) Warehouse Department: Tornado Shelter Area (Yellow Rails): On or about March 12, 2024, and times prior, the employer failed to provide a clear and and sufficient access in front of an electrical panel breaker box for employees use during service and maintenance activities. |
|
Citation ID |
02008 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 II |
Issuance Date |
2024-08-14 |
Abatement Due Date |
2024-08-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Quality Control Department (Laboratory): On or about March 12, 2024, and times prior, the employer failed to effectively close unused knockout hole(s) and opening(s) in a Homeline LOAD CENTER HOM6-12L100 electronic breaker box. |
|
Citation ID |
02009 |
Citaton Type |
Other |
Standard Cited |
19100305 J04 V |
Issuance Date |
2024-08-14 |
Abatement Due Date |
2024-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-11 |
Nr Instances |
2 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(j)(4)(v): The disconnecting means was not readily accessible: a) Warehouse Department: Loading Docks (Elevated Safety Switches): On or about March 12, 2024, and times prior, the employer required employees to use safety switches that were installed approximately 9 feet above the floor and not easily accessible during service and maintenance activities. b) Warehouse Department: Forklift Charging Area (Elevated Safety Switches): On or about March 12, 2024, and times prior, the employer required employees to use safety switches that were installed approximately 9 feet above the floor and not easily accessible during service and maintenance activities. |
|
Citation ID |
02010 |
Citaton Type |
Other |
Standard Cited |
19101200 F06 II |
Issuance Date |
2024-08-14 |
Abatement Due Date |
2024-08-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical Production Department (Fibrous - Wetting Area): On or about March 12, 2024, and at times prior, the employer failed to ensure that the labels for the mineral oil, waste oil, and cleaning solution containers contained the general information regarding the hazards of the chemicals for employees performing wetting activities on the SMOK-E Moisturizer No. 1 machine. |
|
|
342183886
|
0418600
|
2017-03-14
|
50 COUNTY CT, MONTGOMERY, AL, 36105
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-03-14
|
Emphasis |
L: FORKLIFT, N: AMPUTATE
|
Case Closed |
2017-10-26
|
Related Activity
Type |
Referral |
Activity Nr |
1190080 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 F01 II |
Issuance Date |
2017-05-23 |
Abatement Due Date |
2017-06-05 |
Current Penalty |
6800.0 |
Initial Penalty |
12675.0 |
Final Order |
2017-07-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(f)(1)(ii): When lockout or tagout devices temporarily were removed from the energy isolating device and the machine or equipment was energized to test or position the machine, the employees were not removed from the machine or equipment area in accordance to the paragraph (e)(2): a) Machine #9 - 12; On or about March 8, 2017 the employer exposed employees to amputation hazards in that employees were required to troubleshoot - test or position - the overwrap carriage on Machine #9 - 12 while the machine was energized. The employer failed to follow the required sequence of actions as set by the standard when equipment is energized for testing or positioning. Employees were not removed from the machine or equipment area prior to the machine being energized. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2017-05-23 |
Abatement Due Date |
2017-07-21 |
Current Penalty |
6800.0 |
Initial Penalty |
9959.0 |
Final Order |
2017-07-10 |
Nr Instances |
3 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Maintenance Shop; On or about March 14, 2017 and at times prior thereto the employer exposed employees to amputation hazards in that employees were allowed to operate the Sharp Lathe without a chuck guard. b) Production Floor; On or about March 14, 2017 and at times prior thereto the employer exposed employees to amputation, caught-in, and struck-by hazards in that employees were allowed to operate including but not limited to the Shirring Machine #9 - 3 with unguarded rotating parts near the point of operation. c) Production Floor; On or about March 14, 2017 and at times prior thereto the employer exposed employees to amputation, caught-in, and struck-by hazards in that employees were allowed to operate including but not limited to the Shirring Machine #9 - 4 with unguarded rotating parts near the point of operation. |
|
|
341362457
|
0418600
|
2016-03-29
|
50 COUNTRY CT, MONTGOMERY, AL, 36105
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-03-29
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2016-09-07
|
Related Activity
Type |
Referral |
Activity Nr |
1075431 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2016-07-06 |
Abatement Due Date |
2016-07-18 |
Current Penalty |
3840.0 |
Initial Penalty |
4000.0 |
Final Order |
2016-07-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Printing department: On or about March 29, 2016 and at times prior thereto employees were exposed to inhalation hazards from tight-fitting half-mask dual cartridge painting respirator which they used as required by the employer while conducting printing paint mixing operations and cleaning rollers. The paint included but not limited to print mix (fast solvent) and Print mix(Slow solvent) which may cause sensitization by skin contact, harmful by inhalation and irritating to eyes and skin. The employees had not been medically evaluated for respirator use. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100134 F02 |
Issuance Date |
2016-07-06 |
Abatement Due Date |
2016-07-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (a) Printing department: On or about March 29, 2016 and at times prior thereto employees were exposed to inhalation hazards from paint while wearing tight fitting P95 particulate respirator without having been provided with fit test for the specific respirator used. The paint used by employees included but not limited to print mix (fast solvent) and Print mix(Slow solvent) which may cause sensitization by skin contact, harmful by inhalation and irritating to eyes and skin. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2016-07-06 |
Abatement Due Date |
2016-07-18 |
Current Penalty |
3840.0 |
Initial Penalty |
7000.0 |
Final Order |
2016-07-21 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Press machine SMB 4-2: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (electrical and pneumatic), amputation, caught-in and struck-by hazards from press machine SMB 4-2. Employees were allowed to clean rollers and perform service and/or maintenance operations on Press machine SMB 4-2 without being provided with machine specific lockout/tagout procedures. Procedures were not developed, documented and utilized for the control of potentially hazardous energy. Employees cleaned Press machine SMB 4-2 rollers while they were energized. (b) Press machines SMB 4-3: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (electrical and pneumatic) caught-in and struck-by hazards from press machine SMB 4-3. Employees were allowed to clean rollers and perform service and/or maintenance operations on Press machine SMB 4-3 without being provided with machine specific lockout/tagout procedures. Procedures were not developed, documented and utilized for the control of potentially hazardous energy. Employees cleaned Press machine SMB 4-3 rollers while they were energized. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100147 C05 I |
Issuance Date |
2016-07-06 |
Abatement Due Date |
2016-07-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-21 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: (a) Press machine SMB 4-2: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (electrical and pneumatic), amputation, caught-in and struck-by hazards from press machine SMB 4-2. Employees were allowed to clean rollers and perform service and/or maintenance operations on Press machine SMB 4-2 without being provided by their employer with locks or other materials and hardware used for isolating, securing, or blocking machines from energy sources. (b) Press machines SMB 4-3: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (electrical and pneumatic) caught-in and struck-by hazards from press machine SMB 4-3. Employees were allowed to clean rollers and perform service and/or maintenance operations on Press machine SMB 4-3 without being provided by their employer with locks or other materials and hardware used for isolating, securing, or blocking machines from energy sources. (c) Shirring machine 9-9: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (including electrical and pneumatic) caught-in, struck-by and amputation hazards from Shirring machine 9-9; Clams, Over-wrap fingers and shirring head. The employees were allowed to perform maintenance and/or service on Shirring machine 9-9 without being provided by their employer with locks or other materials and hardware used for isolating, securing, or blocking machines from energy sources. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I A |
Issuance Date |
2016-07-06 |
Abatement Due Date |
2016-07-18 |
Current Penalty |
3840.0 |
Initial Penalty |
7000.0 |
Final Order |
2016-07-21 |
Nr Instances |
4 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: (a) Press machine smb 4-2: On or about March 29, 2016 and at times prior thereto employees were exposed to hazardous energies (electrical and pneumatic); in that the authorized employees had not received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. (b) Press machine smb 4-3: On or about March 29, 2016 and at times prior thereto employees were exposed to hazardous energies (electrical and pneumatic); in that the authorized employees had not received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. (c) Shirring machine 9-11: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (including electrical and pneumatic) in that the authorized employees had not received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. (d) Shirring machine 9-12: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (including electrical and pneumatic) in that the authorized employees had not received training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100147 D03 |
Issuance Date |
2016-07-06 |
Abatement Due Date |
2016-08-05 |
Current Penalty |
3840.0 |
Initial Penalty |
7000.0 |
Final Order |
2016-07-21 |
Nr Instances |
5 |
Nr Exposed |
9 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Bubble Trap Machine 6-1: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (including electrical and pneumatic) caught-in, struck-by and amputation hazards from Bubble Trap Machine 6-1. The employees were allowed to perform maintenance and/or servicing on Bubble Trap Machine 6-1 without isolating the machine from the energy sources to prevent accidental start-up of the machine or release of hazardous energy. (b) Tying machine 7-3: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (including electrical and pneumatic) caught-in, struck-by and amputation hazards from Tying Machine 7-3. The employees were allowed to perform maintenance and/or servicing on Tying machine 7-3 without isolating the machine from the energy sources to prevent accidental start-up of the machine or release of hazardous energy. (c) Shirring machine 9-1: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (including electrical and pneumatic) caught-in, struck-by and amputation hazards from Shirring machine 9-1; Clams, over-wrap fingers and shirring head. The employees were allowed to perform maintenance and/or service on Shirring machine 9-1 without isolating the machine from the energy sources to prevent accidental start-up of the machine or release of hazardous energy. (d) Shirring machine 9-9: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (including electrical and pneumatic) caught-in, struck-by and amputation hazards from Shirring machine 9-9; Clams, Over-wrap fingers and shirring head. The employees were allowed to perform maintenance and/or service on Shirring machine 9-9 without isolating the machine from the energy sources to prevent accidental start-up of the machine or release of hazardous energy. (e) Smoke Tower Machine 12-1: On or about March 29, 2016 and at times prior thereto the employer exposed employees to hazardous energies (including electrical and pneumatic) caught-in, struck-by and amputation hazards from Smoke Tower Machine 12-1 rewind motor. The employees were allowed to perform maintenance and/or service on smoke tower machine 12-1 without isolating the machine from the energy sources to prevent accidental start-up of the machine or release of hazardous energy. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2016-07-06 |
Abatement Due Date |
2016-07-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-21 |
Nr Instances |
5 |
Nr Exposed |
9 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Shirring machine 9-1: On or about March 29, 2016 and at times prior thereto the employer exposed employees to caught-by, struck-by and amputation hazards from Shirring machine 9-1; Clams, over-wrap fingers and shirring head. Employees were allowed to perform maintenance and/or service on Shirring machine 9-1 without placing locks and tags on machinery for the purpose of controlling hazardous energy sources. (b) Shirring machine 9-9: On or about March 29, 2016 and at times prior thereto the employer exposed employees to caught-by, struck-by and amputation hazards from Shirring machine 9-9; Clams, Over-wrap fingers and shirring head. Employees were allowed to perform maintenance and/or service on Shirring machine 9-9 without placing locks and tags on machinery for the purpose of controlling hazardous energy sources. (c)Tying machine 7-3: On or about March 29, 2016 and at times prior thereto the employer exposed employees to amputation hazards from Tying Machine knife blade(Fly knife). Employees were allowed to perform maintenance and/or service on Tying machine 7-3 without placing locks and tags on machinery for the purpose of controlling hazardous energy sources. (d)Bubble Trap Machine 6-1: On or about March 29, 2016 and at times prior thereto the employer exposed employees to caught-by, struck-by and amputation hazards from Bubble Trap Machine 6-1. Employees were allowed to perform maintenance and/or service on Bubble trap machine 6-1 without placing locks and tags on machinery for the purpose of controlling hazardous energy sources. (e)Smoke Tower Machine 12-1: On or about March 29, 2016 and at times prior thereto the employer exposed employees to caught-by, struck-by and amputation hazards from Smoke Tower Machine 12-1. Employees were allowed to perform maintenance and/or service on smoke tower machine 12-1 without placing locks and tags on machinery for the purpose of controlling hazardous energy sources. |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2016-07-06 |
Abatement Due Date |
2016-08-05 |
Current Penalty |
3840.0 |
Initial Penalty |
7000.0 |
Final Order |
2016-07-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: (a)Shirring machine 9-11: On or about March 29, 2016 and at times prior thereto the employer exposed employees to amputation hazards in that an employee was allowed to operate shirring machine 9-11 with unguarded blade whose operation exposed an employee to injury. |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2016-07-06 |
Abatement Due Date |
2016-07-14 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-07-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a)Shirring Machine 9-12: On or about March 29, 2016 and at times prior thereto the employer exposed employees to amputation, caught-in and struck-by hazards in that employees were allowed to operate the shirring machine 9-12 with unguarded rotating parts near the point of operation. |
|
|
316304419
|
0418600
|
2012-02-29
|
50 COUNTY COURT, MONTGOMERY, AL, 36105
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-03-01
|
Emphasis |
S: POWERED IND VEHICLE, N: AMPUTATE, L: FORKLIFT, S: AMPUTATIONS, S: ELECTRICAL
|
Case Closed |
2012-06-07
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100178 Q01 |
Issuance Date |
2012-04-03 |
Abatement Due Date |
2012-02-29 |
Initial Penalty |
2550.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2012-04-03 |
Abatement Due Date |
2012-04-04 |
Current Penalty |
2000.0 |
Initial Penalty |
3000.0 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2012-04-03 |
Abatement Due Date |
2012-04-04 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100219 C04 I |
Issuance Date |
2012-04-03 |
Abatement Due Date |
2012-04-13 |
Current Penalty |
2000.0 |
Initial Penalty |
3000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100304 F01 I |
Issuance Date |
2012-04-03 |
Abatement Due Date |
2012-03-01 |
Current Penalty |
1400.0 |
Initial Penalty |
2167.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |