Name: | The Ford Meter Box Company, Inc. |
Jurisdiction: | Alabama |
Legal type: | Foreign Corporation |
Status: | Exists |
Entity Number: | 000-883-157 |
Register Number: | 000883157 |
ZIP code: | 35125 |
County: | Saint Clair |
Place of Formation: | Indiana |
Registered Office Street Address: | 815 MILES PKYPELL CITY, AL 35125 |
Principal Address: | 775 MANCHESTER AVENUEWABASH, IN 46992 |
Name | Role |
---|---|
GENTILE, ZACHARY J JR | Agent |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345020861 | 0418300 | 2020-11-12 | 815 MILES PARKWAY, PELL CITY, AL, 35125 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 1682809 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2021-01-26 |
Current Penalty | 1492.0 |
Initial Penalty | 8953.0 |
Final Order | 2021-02-18 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 10/26/2020 - Fabrication Department, Track Welder, Machine I.D. #F1127, the 6-in gap between the two hold-down metal bars was not guarded exposing employees to caught-in and amputation hazards. |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19100176 A |
Issuance Date | 2021-01-26 |
Current Penalty | 5969.0 |
Initial Penalty | 5969.0 |
Final Order | 2021-02-18 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.176(a): Permanent aisles or passageways were not appropriately marked: (a) On or about 11/12/2020 - Production Area, permanent aisles or passageways were not marked exposing employees to struck-by and crushed-by hazards when walking in the same area where a Hyster, LP Gas, powered industrial truck was operated. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19100037 B04 |
Issuance Date | 2021-01-26 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-02-18 |
Nr Instances | 1 |
Nr Exposed | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: (a) On or about 11/12/2020 - Production Building Area, signs were not posted along the exit access to indicate the direction of travel to the nearest exit door. |
Date of last update: 16 Aug 2024
Sources: Alabama Secretary of State