Search icon

American Excelsior Company

Details

Name: American Excelsior Company
Jurisdiction: Alabama
Legal type: Foreign Corporation
Status: Exists
Entity Number: 000-850-316
Register Number: 000850316
ZIP code: 36104
County: Montgomery
Place of Formation: Texas
Principal Address: 850 AVENUE H EASTARLINGTON, TX 76011
Registered Office Street Address: 2 NORTH JACKSON ST., SUITE 605MONTGOMERY, AL 36104

Agent

Name Role Address
C T CORPORATION SYSTEM Agent 2 NORHT JACKSON STREET SUITE 605MONTGOMERY, AL 36104

Events

Event Date Event Type Old Value New Value
1996-01-03 Name Merged No data Fiberex, Inc.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345124093 0418300 2021-01-22 4032 PARKWAY DRIVE, FLORENCE, AL, 35630
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2021-01-22
Emphasis N: DUSTEXPL
Case Closed 2021-08-12

Related Activity

Type Referral
Activity Nr 1720601
Safety Yes
Type Inspection
Activity Nr 1512412
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19100022 A01
Issuance Date 2021-07-13
Abatement Due Date 2021-08-06
Current Penalty 10942.0
Initial Penalty 10942.0
Final Order 2021-08-05
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition: (a) On or about January 22, 2021 - Blanket line, combustible dust had accumulated on overhead pipes and equipment, greater than one inch in depth in some areas, exposing employees to a fire hazard.
Citation ID 01001B
Citaton Type Other
Standard Cited 19100022 A02
Issuance Date 2021-07-13
Abatement Due Date 2021-08-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-08-05
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(2): The employer did not ensure that the floor of each workroom is maintained in a clean and, to the extent feasible, in a dry condition. The employer did not ensure that when wet processes are used, drainage is be maintained and, to the extent feasible, dry standing places, such as false floors, platforms, and mats are provided: (a) On or about January 22, 2021 - Blanket line, combustible dust had accumulated on the floor of the blanket line and around the re-baler, greater than one inch in depth in some areas, exposing employees to a fire hazard.
Citation ID 01001C
Citaton Type Other
Standard Cited 19100178 C02 VII
Issuance Date 2021-07-13
Abatement Due Date 2021-08-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-08-05
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(c)(2)(vii): Power-operated industrial trucks designated as DY, EE, or EX were not used in atmospheres in which combustible dust is not normally in suspension in the air by normal operation of equipment or apparatus but where deposits or accumulations of such dust could be ignited by arcs or sparks originating in the truck: (a) On or about January 22, 2021 - Blanket line, employees were operating propane-powered forklifts where combustible dust had accumulated on overhead pipes and equipment, greater than one inch in depth in some areas, exposing employees to a fire hazard.
Citation ID 01001D
Citaton Type Other
Standard Cited 19100307 C
Issuance Date 2021-07-13
Abatement Due Date 2021-08-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-08-05
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: (a) On or about January 22, 2021 - Blanket line, combustible dust had accumulated on motors, control panels, and electrical boxes, greater than one inch in depth in some areas, exposing employees to a fire hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2021-07-13
Abatement Due Date 2021-08-06
Current Penalty 10239.75
Initial Penalty 13653.0
Final Order 2021-08-05
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: (a) On or about January 14, 2021 - Re-baler on blanket line, employees were exposed to struck-by hazards when employees could reach over the baler hopper guard and reach into the baler while the ram was operating.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100219 D01
Issuance Date 2021-07-13
Abatement Due Date 2021-08-06
Current Penalty 4103.25
Initial Penalty 5471.0
Final Order 2021-08-05
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) On or about January 22, 2021 - Blanket line, employees were exposed to caught-in hazards when the conveyor pulley approximately 5 feet from the floor was not guarded on the bottom and one side.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100219 E03 I
Issuance Date 2021-07-13
Abatement Due Date 2021-08-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-08-05
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): (a) On or about January 22, 2021 - Blanket line, employees were exposed to caught-in hazards when the drive belt for the straw conveyor approximately 5 feet from the floor was not guarded on the bottom and one side.
Citation ID 02001
Citaton Type Other
Standard Cited 19100146 C03
Issuance Date 2021-07-13
Abatement Due Date 2021-08-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-08-05
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(c)(3): When the employer decided that its employees would not enter permit spaces, the employer did not comply with 29 CFR 1910.146(c)(1), 29 CFR 1910.146(c)(2), 29 CFR 1910.146(c)(6), and 29 CFR 1910.146(c)(8): (a) On or about January 22, 2021 - Blanket line, the employer had not evaluated the workplace to determine that the blanket line re-baler was a confined space, evaluated work performed by employees to insure that employees did not break the plane of the confined space nor posted warning signage.

Date of last update: 16 Aug 2024

Sources: Alabama Secretary of State