Name: | MILLPORT LUMBER & MANUFACTURING, L.L.C. |
Jurisdiction: | Alabama |
Legal type: | Domestic Limited Liability Company |
Status: | Exists |
Date of registration: | 07 Jan 1994 (31 years ago) |
Entity Number: | 000-650-184 |
Register Number: | 000650184 |
ZIP code: | 35576 |
County: | Lamar |
Place of Formation: | Lamar County |
Registered Office Mailing Address: | PO BOX 407MILLPORT, AL 35576 |
Principal Address: | 462 COLUMBUS STREETMILLPORT, AL 35576 |
Activities
ANY LAWFUL PURPOSE OR PURPOSES
Name | Role | Address |
---|---|---|
MAYERS, RICKY | Agent | 1651 CO RD 27MILLPORT, AL 35576 |
Name | Role | Address |
---|---|---|
MAYERS, RICKY | Member | 1651 CO RD 27MILLPORT, AL 35576 |
JACKSON, JEFF | Member | 152 JUNIPER STREETWINFIELD, AL 35594 |
MAYERS, BRETT S | Member | COUNTY ROAD 27MILLPORT, AL 35576 |
JACKSON, WILLIAM H | Member | 3492 HIGHWAY 50 EASTCOLUMBUS, MS 39702 |
Name | Role | Address |
---|---|---|
JACKSON, JEFF | Organizer | 152 JUNIPER STREETWINFIELD, AL 35594 |
MAYERS, BRETT S | Organizer | COUNTY ROAD 27MILLPORT, AL 35576 |
JACKSON, WILLIAM H | Organizer | 3492 HIGHWAY 50 EASTCOLUMBUS, MS 39702 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
336668009 | 0418300 | 2012-10-03 | 463 COLUMBUS STREET, MILLPORT, AL, 35576 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19100303 B02 |
Issuance Date | 2012-10-30 |
Current Penalty | 720.0 |
Initial Penalty | 1200.0 |
Final Order | 2012-11-29 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) On or about October 3, 2102 - Resaw Area, a relocatable power tap was series-connected to two (2) extension cords. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19100305 G01 IV A |
Issuance Date | 2012-10-30 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-11-29 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) On or about October 3, 2012 - Resaw Area, two (2) extension cords were used in place of permanent wiring. |
Citation ID | 02001A |
Citaton Type | Other |
Standard Cited | 19040010 A |
Issuance Date | 2012-10-30 |
Abatement Due Date | 2012-11-09 |
Current Penalty | 240.0 |
Initial Penalty | 400.0 |
Final Order | 2012-11-29 |
Nr Instances | 1 |
Nr Exposed | 11 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1904.10(a): The employer did not record a hearing loss case on the OSHA 300 log when employee's hearing test (audiogram) reveals that the employee has experienced a work-related Standard Threshold Shift (STS) in hearing in one or both ears, and the employee's total hearing level is 25 decibels (dB) or more above audiometric zero (averaged at 2000, 3000, and 4000 Hz) in the same ear(s) as the STS, you must record the case on the OSHA 300 Log: (a) On or about October 3, 2012 - Facility, a hearing loss case reported on July 25, 2012 had not been recorded. |
Citation ID | 02001B |
Citaton Type | Other |
Standard Cited | 19040029 A |
Issuance Date | 2012-10-30 |
Abatement Due Date | 2012-11-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-11-29 |
Nr Instances | 1 |
Nr Exposed | 11 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent. (a) On or about October 3, 2012 - Facility, OSHA 300 and 300A forms or equivalent were not maintained. |
Citation ID | 02002 |
Citaton Type | Other |
Standard Cited | 19100132 D02 |
Issuance Date | 2012-10-30 |
Abatement Due Date | 2012-11-29 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-11-29 |
Nr Instances | 1 |
Nr Exposed | 11 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment had been performed through written certification that identified the workplace evaluated; the person certifying that the evaluation had been performed; the date(s) of the hazard assessment; and, identified the document as a certification of the hazard assessment: (a) On or about October 3, 2012 - Facility, no written certification to verify the hazard assessment had been performed. |
Citation ID | 02003 |
Citaton Type | Other |
Standard Cited | 19100133 A02 |
Issuance Date | 2012-10-30 |
Abatement Due Date | 2012-11-06 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-11-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.133(a)(2): The employer shall ensure that each affected employee uses eye protection that provides side protection when there is a hazard from flying objects. Detachable side protectors (e.g. clip-on or slide-on side shields) meeting the pertinent requirements of this section are acceptable: (a) On or about October 3, 2012 - Baker Resaw, an employee wore eye protection that was not equipped with side protection. |
Date of last update: 15 Aug 2024
Sources: Alabama Secretary of State