Search icon

Grede II LLC

Details

Name: Grede II LLC
Jurisdiction: Alabama
Legal type: Foreign Limited Liability Company
Status: Exists
Date of registration: 05 Feb 2010 (15 years ago)
Entity Number: 000-619-016
Register Number: 000619016
ZIP code: 36104
County: Montgomery
Place of Formation: Delaware
Principal Address: 27275 HAGGERTY ROAD STE 420NOVI, MI 48377
Registered Office Street Address: 2 NORTH JACKSON ST., SUITE 605MONTGOMERY, AL 36104

Activities MANUFACTURING

Agent

Name Role Address
C T CORPORATION SYSTEM Agent 2 NORHT JACKSON STREET SUITE 605MONTGOMERY, AL 36104

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347775405 0418600 2024-09-05 210 ANN AVE, BREWTON, AL, 36426
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-09-05
Case Closed 2024-10-04

Related Activity

Type Referral
Activity Nr 2208758
Safety Yes
347708356 0418600 2024-08-23 210 ANN AVE, BREWTON, AL, 36426
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-08-23

Related Activity

Type Referral
Activity Nr 2203564
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100335 A01 I
Issuance Date 2024-10-07
Current Penalty 6856.0
Initial Penalty 9795.0
Final Order 2024-11-14
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed. a) Transformer Yard - 210 Ann Ave. Brewton AL.; On or about August 21, 2024 and at times prior thereto the employer exposed employees to electrical/arc flash hazards in that employees were to perform maintenance on a switch gear for the #4 furnace disconnect exposing themselves to live components operating at 12,479 volts without using the correct rated electrical protective equipment (PPE).
346363724 0418600 2022-11-28 210 ANN AVE, BREWTON, AL, 36426
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2023-02-22
Emphasis L: LEAD, N: PMETALS
Case Closed 2023-05-23

Related Activity

Type Complaint
Activity Nr 1969279
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100028 B03 II
Issuance Date 2023-04-14
Abatement Due Date 2023-05-03
Current Penalty 3500.0
Initial Penalty 5692.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.28(b)(3)(ii): The employer did not ensure that each employee be protected from tripping into or stepping into or through any hole that is less than 4 feet (1.2 m) above a lower level by covers or guardrail systems. a) Melt Deck, Alloy Feeder Area; On or about November 28, 2022: the employer exposed employees to slip/trip hazards in that employees were allowed to walk and work around a floor hole (trash/scrap location) that was not protected by a cover or guardrail system.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2023-04-14
Current Penalty 3500.0
Initial Penalty 5692.0
Final Order 2023-05-03
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Under the CID machine; On or about November 28, 2022: the employer exposed employees to caught-in hazards in that employees were allowed to perform cleaning and maintenance task near an unguarded rotating counter on the CID machine.
344629449 0418600 2020-02-11 210 ANN AVE, BREWTON, AL, 36426
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2020-02-12
Emphasis L: FORKLIFT, N: DUSTEXPL
Case Closed 2020-08-13

Related Activity

Type Complaint
Activity Nr 1541882
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100022 D02
Issuance Date 2020-03-26
Abatement Due Date 2020-04-07
Current Penalty 3750.0
Initial Penalty 4916.0
Final Order 2020-05-22
Nr Instances 2
Nr Exposed 8
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(d)(2): The employer did not ensure hazardous conditions on walking-working surfaces were corrected or repaired before an employee used the walking-working surface again. When the correction or repair cannot be made immediately, the hazard was not guarded to prevent employees from using the walking-working surface until the hazard is corrected or repaired: a) Pouring Area, grating around pressure pourer A; On or about February 11, 2019 and at times prior to, the employer failed to repair walking-working surfaces after areas had been cut out to gain access to the pressure pourer for maintenance while still allowing the area to be used as access and egress. b) Pouring Area, upper mezzanine around pressure pourer B; On or about February 11, 2019 and at times prior to, the employer failed to repair walking-working surfaces that contained holes in the grating while requiring employees to work in the area.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100028 B01 I
Issuance Date 2020-03-26
Abatement Due Date 2020-04-07
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-05-22
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) Pour area, Pressure Pour line #B; On or about February 11, 2020 and at times prior to the employer required that employees work at an area at the pressure pourer on line #B while being exposed to an unprotected edge exposing the employee to fall hazards of seven feet.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100178 P01
Issuance Date 2020-03-26
Abatement Due Date 2020-04-07
Current Penalty 3750.0
Initial Penalty 6554.0
Final Order 2020-05-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): a) Forklift #1, maintenance shop; On or about February 11, 2020 and at times prior to the employer allowed a forklift to be used, or put in service that had visible issues including but not limited to missing/illegible data plates, leaking hydraulic oil, cracked roll cages, ripped hoses, and low sounding horns without verifying that these issues were fixed before being returned to service exposing employees to struck-by hazards.
Citation ID 01003
Citaton Type Other
Standard Cited 19100253 B02 II
Issuance Date 2020-03-26
Current Penalty 3750.0
Initial Penalty 4916.0
Final Order 2020-05-22
Nr Instances 3
Nr Exposed 8
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a) Maintenance shop; On or about February 11, 2020 and at time prior the employer did not ensure that pressurized cylinders were stored in a way that they could not be knocked over or damaged by passing employees or work procedures exposing the employees to struck by hazards. b) Canister storage area; On or about February 11, 2020 and at time prior the employer did not ensure that pressurized cylinders were stored in a way that they could not be knocked over or damaged by passing employees or work procedures exposing the employees to struck by hazards. c) Forklift maintenance shop; On or about February 11, 2020 and at time prior the employer did not ensure that pressurized cylinders were stored in a way that they could not be knocked over or damaged by passing employees or work procedures exposing the employees to struck by hazards.
Citation ID 01004
Citaton Type Other
Standard Cited 19100253 B04 III
Issuance Date 2020-03-26
Current Penalty 3750.0
Initial Penalty 6554.0
Final Order 2020-05-22
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: a) Maintenance shop; On or about February 11, 2020 and at times prior to the employer allowed oxygen bottles that were not in use to be stored at the area were acetylene torch cutting was conducted without being separated by a minimum distance of 20 feet or an approved firewall exposing the employees to explosion hazards.
343920682 0418600 2019-04-10 210 ANN AVE, BREWTON, AL, 36426
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2019-08-15
Emphasis N: LEAD, L: LEAD, N: CHROME6, N: DUSTEXPL, N: PMETALS, P: CHROME6
Case Closed 2019-10-09

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19101030 F03
Issuance Date 2019-09-13
Abatement Due Date 2019-09-23
Current Penalty 0.0
Initial Penalty 4262.0
Final Order 2019-10-04
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1030(f)(3): Following a report of an exposure incident, the employer did not make immediately available to the exposed employee a confidential medical evaluation or follow-up: Facility wide: On or about July 11, 2019 and at times prior to, the employer exposed employees to blood borne pathogen hazards from assisting in head injury that occurred and did not immediately make available a medical evaluation or post exposure consultation.
Citation ID 02001
Citaton Type Other
Standard Cited 19100022 D02
Issuance Date 2019-09-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-10-04
Nr Instances 1
Nr Exposed 6
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(d)(2): The employer did not ensure hazardous conditions on walking-working surfaces were corrected or repaired before an employee used the walking-working surface again. When the correction or repair cannot be made immediately, the hazard was not guarded to prevent employees from using the walking-working surface until the hazard is corrected or repaired: a) Degate Line: On or about July 11, 2019 and at times prior to, the employer exposed employees to trip and fall hazards from openings in the walking and working surface over the scrap conveyor due to removed grating.
341600252 0418300 2016-07-06 2217 CAROLINA AVE, BESSEMER, AL, 35020
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2016-12-08
Case Closed 2017-02-15

Related Activity

Type Referral
Activity Nr 1107366
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2016-12-14
Abatement Due Date 2017-01-11
Current Penalty 8642.2
Initial Penalty 12346.0
Final Order 2017-02-01
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees skimming slag from Bull Ladles in the Pouring Department were exposed to a burn hazard: (a) On or about 6/28/2016 - Pouring Department, a Bull Ladle pusher received second and third degree burns when molten metal erupted while slag was being removed from the ladle.
341362630 0418300 2016-03-30 2217 CAROLINA AVENUE, BESSEMER, AL, 35020
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2016-03-30
Emphasis N: AMPUTATE
Case Closed 2016-09-14

Related Activity

Type Referral
Activity Nr 1075280
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2016-06-16
Current Penalty 6600.0
Initial Penalty 6600.0
Final Order 2016-07-14
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 03/24/2016 - DISA Summit #2, Transfer Car Line, employees were not protected from exposure to the location where the large metal transfer car came into contact with the inside rail wall.
340694116 0418600 2015-06-09 1244 SELLFIELD ROAD, SELMA, AL, 36701
Inspection Type Planned
Scope NoInspection
Safety/Health Health
Close Conference 2015-06-09
Emphasis P: CHROME6, N: CHROME6
Case Closed 2015-06-16
338999774 0418600 2013-04-09 210 ANN AVE, BREWTON, AL, 36426
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-04-09
Emphasis N: AMPUTATE
Case Closed 2013-06-03

Related Activity

Type Complaint
Activity Nr 812380
Safety Yes
339002222 0418300 2013-04-08 2217 CAROLINA AVENUE, BESSEMER, AL, 35020
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2013-07-01
Emphasis N: CHROME6, P: CHROME6
Case Closed 2013-08-01

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19101026 D01
Issuance Date 2013-07-03
Abatement Due Date 2013-08-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-01
Nr Instances 1
Nr Exposed 22
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average (TWA) exposure for each employee exposed to chromium (VI): (a) On or about April 8, 2013 - Foundry, the employer did not determine the 8-hour TWA exposure for employees, such as, but not limited to, furnace operators, DISA bull pushers and iron pourers engaged in melting and pouring of molten metal. Employees were sampled for exposure to Hexavalent Chromium during one shift on April 26, 2013. Sample results ranged from 0.00006 mg/3 to 0.00009 mg/m3. The employer may use these sampling results to meet the initial monitoring requirement for Hexavalent Chromium or perform additional monitoring.
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2013-07-24
Case Closed 2013-09-17

Related Activity

Type Complaint
Activity Nr 805968
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19100027 C04
Issuance Date 2013-08-09
Current Penalty 2000.0
Initial Penalty 5000.0
Final Order 2013-08-27
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.27(c)(4): The employer did not install fixed ladders with at least 7 inches of clearance from the centerline of the rung to the nearest permanent object in the back of the ladder: (a) On or about 03/01/13 - Pangborn shot blast machine, the fixed ladder rung did not have sufficient clearance to climb or descend the ladder.
Citation ID 01001B
Citaton Type Other
Standard Cited 19100027 B01 III
Issuance Date 2013-08-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-08-27
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.27(b)(1)(iii): The minimum clear length of rungs or cleats was not 16 inches: (a) On or about 03/01/13 - Goff cleaning machine, the rungs on the access ladder were 12 inches in length.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100178 E02
Issuance Date 2013-08-09
Abatement Due Date 2013-09-05
Current Penalty 3000.0
Initial Penalty 4000.0
Final Order 2013-08-27
Nr Instances 2
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(e)(2): Fork trucks, where the load presents a hazard, were not equipped with vertical load backrest extensions: (a) On or about 03/01/13 - Furnace areas, employees were using a forklift with no vertical load backrest extensions. (b) On or about 03/01/13 - Maintenance, employees were using a forklift with no vertical load backrest extensions.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100303 B07 IV
Issuance Date 2013-08-09
Abatement Due Date 2013-08-29
Current Penalty 3000.0
Initial Penalty 5000.0
Final Order 2013-08-27
Nr Instances 9
Nr Exposed 7
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(7)(iv): There were damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action or overheating: (a) On or about 03/01/13 - West wall under #3 and #4 furnaces, 110-volt panel disconnects were not functional. (b) On or about 03/01/13 - #1 and #2 furnace preheater and charge control, 480-volt disconnects have broken and missing parts. (c) On or about 03/01/13 - B line baghouse and wheelabrator, 480-volt disconnects have broken and missing parts. (d) On or about 03/01/13 - Goff and Pangborn machines, 480-volt disconnects were not functional.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100332 B01
Issuance Date 2013-08-09
Abatement Due Date 2013-08-29
Current Penalty 5000.0
Initial Penalty 7000.0
Final Order 2013-08-27
Nr Instances 3
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: (a) On or about 03/01/13 - Maintenance, some employees are working in and around live electrical parts without training pertaining to their respective job assignments.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19100137 B02 II
Issuance Date 2013-08-09
Abatement Due Date 2013-08-21
Current Penalty 0.0
Initial Penalty 5000.0
Final Order 2013-08-27
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.137(b)(2)(ii): Insulating gloves were not given an air test prior to each day's usage: (a) On or about 03/01/13 - Maintenance department, employees replacing/repairing high voltage fuses and equipment were not air testing rubber insulating gloves prior to use.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100335 A01
Issuance Date 2013-08-09
Abatement Due Date 2013-08-21
Current Penalty 2500.0
Initial Penalty 5000.0
Final Order 2013-08-27
Nr Instances 2
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.335(a)(1): Employees working in areas where there were potential electrical hazards were not provided with, and/or did not use, electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: (a) On or about 03/01/13 - Maintenance, employees performing work in and around live electrical circuits did not use lower body protection, such as pants, when working in areas where there were potential electrical hazards.
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2011-12-21
Emphasis S: POWERED IND VEHICLE, S: AMPUTATIONS, S: STRUCK-BY, N: AMPUTATE
Case Closed 2012-06-04

Related Activity

Type Complaint
Activity Nr 208404236
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100215 A04
Issuance Date 2012-04-12
Abatement Due Date 2012-04-20
Current Penalty 2138.0
Initial Penalty 3825.0
Nr Instances 1
Nr Exposed 3
Gravity 05
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100215 B09
Issuance Date 2012-04-12
Abatement Due Date 2012-04-20
Nr Instances 1
Nr Exposed 3
Gravity 05
Citation ID 01002A
Citaton Type Other
Standard Cited 19100305 G02 III
Issuance Date 2012-04-12
Abatement Due Date 2012-04-23
Current Penalty 2138.0
Initial Penalty 3825.0
Nr Instances 3
Nr Exposed 3
Gravity 05
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100305 G02 II
Issuance Date 2012-04-12
Abatement Due Date 2012-04-18
Nr Instances 2
Nr Exposed 3
Gravity 05
Citation ID 02001
Citaton Type Other
Standard Cited 19040032 B03
Issuance Date 2012-04-12
Abatement Due Date 2012-04-20
Current Penalty 900.0
Initial Penalty 900.0
Nr Instances 4
Nr Exposed 3
Gravity 00
Citation ID 02002
Citaton Type Other
Standard Cited 19100303 B07 IV
Issuance Date 2012-04-12
Abatement Due Date 2012-04-20
Nr Instances 2
Nr Exposed 3
Gravity 01
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2010-07-21
Emphasis N: RKNEP
Case Closed 2010-07-21

Date of last update: 15 Aug 2024