Search icon

Outokumpu Stainless USA, LLC

Details

Name: Outokumpu Stainless USA, LLC
Jurisdiction: Alabama
Legal type: Foreign Limited Liability Company
Status: Exists
Date of registration: 17 May 2007 (18 years ago)
Entity Number: 000-613-902
Register Number: 000613902
Historical Names: ThyssenKrupp Stainless USA, LLC
ZIP code: 36104
County: Montgomery
Place of Formation: Delaware
Principal Address: 1 THYSSENKRUPP DRIVECALVERT, AL 36513-1300
Registered Office Street Address: 641 SOUTH LAWRENCE STREETMONTGOMERY, AL 36104

Activities CONSTRUCTION/OPERATION OF FACILITY
MFG/SALE OF STAINLESS STEEL

Agent

Name Role Address
CORPORATION SERVICE COMPANY INC Agent 251 LITTLE FALLS DRIVEWILMINGTON, DE 19808

Events

Event Date Event Type Old Value New Value
2013-01-15 Name Change ThyssenKrupp Stainless USA, LLC Outokumpu Stainless USA, LLC

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346643521 0418600 2023-04-19 1 STEEL MILL DRIVE PAUL BAYOU GATE, CALVERT, AL, 36513
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2023-06-26
Case Closed 2023-07-07

Related Activity

Type Inspection
Activity Nr 1664347
Safety Yes
343795167 0418600 2019-02-20 1 STEEL DRIVE, CALVERT, AL, 36513
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2019-02-20
Emphasis L: LEAD, N: CHROME6, N: LEAD
Case Closed 2019-04-09

Related Activity

Type Complaint
Activity Nr 1426980
Health Yes
342425055 0418600 2017-06-26 1 THYSSENKRUPP DR, CALVERT, AL, 36513
Inspection Type Planned
Scope Complete
Safety/Health Health
Close Conference 2017-08-22
Emphasis N: CHROME6, N: DUSTEXPL, N: LEAD, P: CHROME6
Case Closed 2017-10-13
339902462 0418600 2014-06-11 1 THYSSENKRUPP DRIVE, CALVERT, AL, 36513
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2014-06-11
Case Closed 2015-01-14

Related Activity

Type Complaint
Activity Nr 892368
Safety Yes
Type Inspection
Activity Nr 979378
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100147 F03 II D
Issuance Date 2014-12-01
Abatement Due Date 2014-12-18
Current Penalty 2000.0
Initial Penalty 3375.0
Final Order 2014-12-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee shall affix a personal lockout or tagout device to the group lockout device prior to working on the machine or equipment: a) EAF system: On or about June 2, 2014 during the inspection, the employer did not ensure the outside personnel's authorized employees affixed a personal lockout and/or tag out device to the EAF system while conducting contracted services in the dropout chamber.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100147 F02 I
Issuance Date 2014-12-01
Abatement Due Date 2014-12-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-12-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(f)(2)(i): When outside servicing personnel are to be engaged in activities covered by the scope and application of this standard, the on-site employer and the outside employer did not inform each other of their respective lockout or tagout procedures: a) EAF system: On or about June 2, 2014 During the inspection, the employer and contractor did not inform each other of respective Control of Hazardous Energy (lockout tag out) programs applicable to potential inadvertent startup of the EAF system.
339801391 0418600 2014-06-10 1 THYSSENKRUPP DR., CALVERT, AL, 36513
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2014-06-10
Emphasis L: LEAD, N: LEAD
Case Closed 2014-08-21

Related Activity

Type Complaint
Activity Nr 892985
Health Yes

Date of last update: 15 Aug 2024

Sources: Alabama Secretary of State