DEALNEY, JASMYN | Agent |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343308037 | 0418600 | 2018-07-18 | 24680 ADALADE LN. BELLATON SUBDIVISION, DAPHNE, AL, 36526 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2018-08-01 |
Current Penalty | 3326.0 |
Initial Penalty | 3326.0 |
Final Order | 2018-09-04 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At 24680 Adalade Lane, Daphne, Alabama: On or about July 18, 2018 and at times prior; the employer allowed his employees to perform framing activities without fall protection exposing his employees to a fall hazard of 10.7 feet to the concrete floor below. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2018-08-01 |
Current Penalty | 2217.0 |
Initial Penalty | 2217.0 |
Final Order | 2018-09-04 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At 24680 Adalade Lane, Daphne, Alabama: On or about July 18, 2018 and at times prior; the employer allowed his employees to use a ladder to gain access to the roof and the rails of the ladder did not extend three feet above the landing to provide safe access exposing his employees to a fall hazard of 11 feet to the ground below. |