Activities
RESIDENTIAL/COMMERCIAL ROOFING SERVICES
Name | Role |
---|---|
GOODSON, MIKE | Agent |
Name | Role |
---|---|
GOODSON, MIKE | Member |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
338907025 | 0418600 | 2013-02-13 | 192 MALVERN RD., DOTHAN, AL, 36301 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2013-03-08 |
Abatement Due Date | 2013-03-18 |
Current Penalty | 500.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-03-19 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents. a) On February 13, 2013 and at times prior; the employer failed to provide eye protection to employees working with a nailgun. |
Citation ID | 02001 |
Citaton Type | Repeat |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-03-08 |
Abatement Due Date | 2013-03-18 |
Current Penalty | 2500.0 |
Initial Penalty | 3200.0 |
Final Order | 2013-03-19 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. a) On or about February 13, 2013 and at times prior; the employer did not ensure a fall protection method was implemented and/or used while an employee was working at the roof area which exposed the employee to falls of 9 feet from the eave to the ground below. Mike Goodson Roofing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent which was contained in OSHA inspection number 315457242, citation 1, item 1, and was affirmed as a final order on June 28, 2011 with respect to a workplace located at 3618 Oakridge Lane, Dothan AL |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2011-06-15 |
Emphasis | S: RESIDENTIAL CONSTR, L: FALL, S: FALL FROM HEIGHT |
Case Closed | 2011-07-07 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2011-06-28 |
Abatement Due Date | 2011-06-15 |
Current Penalty | 2040.0 |
Initial Penalty | 2040.0 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 05 |