345454375
|
0418300
|
2021-07-28
|
515 TYSON ROAD, ASHLAND, AL, 36251
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-01-24
|
Case Closed |
2022-01-26
|
Related Activity
Type |
Complaint |
Activity Nr |
1789488 |
Safety |
Yes |
|
|
345347058
|
0418300
|
2021-06-07
|
515 TYSON ROAD, ASHLAND, AL, 36251
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-06-07
|
Emphasis |
L: FOODPRO
|
Case Closed |
2024-07-18
|
Related Activity
Type |
Referral |
Activity Nr |
1772631 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II A |
Issuance Date |
2021-12-07 |
Abatement Due Date |
2022-01-04 |
Current Penalty |
0.0 |
Initial Penalty |
13653.0 |
Contest Date |
2022-01-06 |
Final Order |
2022-07-05 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii)(A): The Energy Control Procedures did not include a specific statement of the intended use of the procedure: (a) On or about 6/7/2021 - 515 Tyson Road, Ashland, Alabama, in the Second Processing Department, employees using the ECP for the Leg Quarter Hopper Scale, Line #1 and #2 to access the point of operation to perform work were exposed to machine hazards such as struck by, and caught by from energized parts because the ECP did not include a specific statement of the intended use of the procedure. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II B |
Issuance Date |
2021-12-07 |
Abatement Due Date |
2022-01-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2022-01-06 |
Final Order |
2022-07-05 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii)(B):The energy control procedure did not include specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) On or about 6/7/2021 - 515 Tyson Road, Ashland, Alabama, in the Second Processing Department, employees using the ECP for the Leg Quarter Hopper Scale, Line #1 and #2 to access the point of operation to perform work were exposed to machine hazards such as struck by, and caught by from energized parts because the ECP did not include specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II C |
Issuance Date |
2021-12-07 |
Abatement Due Date |
2022-01-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2022-01-06 |
Final Order |
2022-07-05 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii)(C):The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. (a) On or about 6/7/2021 - 515 Tyson Road, Ashland, Alabama, in the Second Processing Department, employees using the ECP for the Leg Quarter Hopper Scale, Line #1 and #2 to access the point of operation to perform work were exposed to machine hazards such as struck by, and caught by from energized parts because the ECP did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. |
|
Citation ID |
01001D |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 II D |
Issuance Date |
2021-12-07 |
Abatement Due Date |
2022-01-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2022-01-06 |
Final Order |
2022-07-05 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii)(D):The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control. (a) On or about 6/7/2021 - 515 Tyson Road, Ashland, Alabama, in the Second Processing Department, employees using the ECP for the Leg Quarter Hopper Scale, Line #1 and #2 to access the point of operation to perform work were exposed to machine hazards such as struck by, and caught by from energized parts because the ECP did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy controls. |
|
|
344323423
|
0418300
|
2019-09-17
|
515 TYSON ROAD, ASHLAND, AL, 36251
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-09-17
|
Case Closed |
2020-03-03
|
Related Activity
Type |
Inspection |
Activity Nr |
1273940 |
Safety |
Yes |
|
|
342739406
|
0418300
|
2017-10-30
|
515 TYSON ROAD, ASHLAND, AL, 36251
|
|
Inspection Type |
Fat/Cat
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-10-30
|
Case Closed |
2019-04-12
|
Related Activity
Type |
Accident |
Activity Nr |
1278906 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2018-04-03 |
Abatement Due Date |
2018-04-13 |
Current Penalty |
0.0 |
Initial Penalty |
12934.0 |
Contest Date |
2018-04-19 |
Final Order |
2019-03-11 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about October 29, 2017 - Rehang Area, a procedure was not developed, documented, and utilized to control potentially hazardous energy when employees were sanitizing or performing service and maintenance activities on the Meyn Automatic Rehanger Machines between the Kill Line and Evisceration lines 1 and 2 exposing employees to caught-in hazards. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100147 C07 III B |
Issuance Date |
2018-04-03 |
Abatement Due Date |
2019-05-13 |
Current Penalty |
6566.0 |
Initial Penalty |
12934.0 |
Contest Date |
2018-04-19 |
Final Order |
2019-03-11 |
Nr Instances |
1 |
Nr Exposed |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining shall also be conducted whenever a periodic inspection under paragraph (c)(6) of this section reveals, or whenever the employer has reason to believe that there are deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: (a) On or about October 29, 2017 - Rehang Area, employees who clean, service, and maintain the Meyn Automatic Rehang Machines between the Kill Line and Evisceration Lines 1 and 2 had not received training on where to apply the three locks on the electrical breakers in order to ensure energy isolation. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2018-04-03 |
Current Penalty |
12934.0 |
Initial Penalty |
12934.0 |
Contest Date |
2018-04-19 |
Final Order |
2019-03-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to caught-in and struck-by hazards: (a) On or about October 29, 2017 - Rehang Area, the guarding was not adequate on the Meyn Rehanger Machines to protect employees from the rotating parts and ingoing nip points of the shackles and equipment, to include but not limited to the sunflower wheel. Among other methods, one feasible and acceptable method to correct these hazards would be to ensure that proper guarding is utilized to protect employees working in close vicinity to the moving equipment as addressed in American Society of Mechanical Engineers (ASME) B20.1-2003 "Safety Standard for Conveyors and Related Equipment" section 5.9.1.2 Interfacing of Equipment that states "when two or more pieces of equipment are interfaced, special attention shall be given to the interfaced area to ensure the presence of adequate guarding and safety devices. |
|
|
340509769
|
0418300
|
2015-03-30
|
515 TYSON ROAD, ASHLAND, AL, 36251
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-06-02
|
Emphasis |
L: FOODPRO, P: AMPUTATE, N: AMPUTATE
|
Case Closed |
2015-07-07
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100254 B04 IV |
Issuance Date |
2015-06-02 |
Abatement Due Date |
2015-06-12 |
Current Penalty |
1125.0 |
Initial Penalty |
2250.0 |
Final Order |
2015-06-25 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.254(b)(4)(iv): Terminals for welding leads were not protected from accidental contact by personnel or metal objects: (a) On or about 03/30/15 - Old Maintenance shop, Lincoln IdealArc Welding Machine, welding lead terminals were not protected. |
|
|
313143729
|
0418300
|
2009-05-27
|
515 TYSON ROAD, ASHLAND, AL, 36251
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2009-09-30
|
Emphasis |
L: POULTRY, N: FIELDSAN, S: AMPUTATIONS
|
Case Closed |
2010-09-08
|
Related Activity
Type |
Complaint |
Activity Nr |
205693401 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2009-10-05 |
Abatement Due Date |
2009-10-14 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Contest Date |
2009-10-26 |
Final Order |
2010-05-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
Hazard |
FALLING |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2009-10-05 |
Abatement Due Date |
2009-10-15 |
Current Penalty |
5000.0 |
Initial Penalty |
5000.0 |
Contest Date |
2009-10-26 |
Final Order |
2010-05-06 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
|
|