Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-03-09
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2016-07-08
|
Related Activity
Type |
Referral |
Activity Nr |
1068351 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2016-05-24 |
Abatement Due Date |
2016-06-24 |
Current Penalty |
960.0 |
Initial Penalty |
1600.0 |
Final Order |
2016-06-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) On or about 03/09/2016 - Facility, periodic inspections were not performed for all equipment such as, but not limited to, the Couvrot Mixer #1, North and South Buttoning Machines, Molding Area Traverse Cart, Molding Overhead Crane, Cage Machine, and Wire Cutting Machine. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2016-05-24 |
Abatement Due Date |
2016-06-06 |
Current Penalty |
1440.0 |
Initial Penalty |
2400.0 |
Final Order |
2016-06-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 02/29/2016 - Machine Shop, JET Combination Belt/Disc Sander, Model #JSG-6DC, Serial #01103187, the gap between the table edge and the abrasive disc was not maintained at 1/16 inch exposing employees to point of operation hazards. (b) On or about 03/09/2016 - Machine Shop, ACRA 12 Speed Heavy Duty Drill Press, Model #RL 79DPF12343, the drill press was not equipped with a guard. |
|
|