341039824
|
0418300
|
2015-11-05
|
915 STEWART AVENUE SE, ATTALLA, AL, 35954
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2015-11-13
|
Emphasis |
N: NURSING
|
Case Closed |
2016-03-16
|
Related Activity
Type |
Referral |
Activity Nr |
1034817 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100022 A01 |
Issuance Date |
2016-02-02 |
Abatement Due Date |
2016-03-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-03-07 |
Nr Instances |
2 |
Nr Exposed |
137 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition: a) On or about 11/5/2015 - North Hall, floor tiles around the drain were cracked and chipped exposing employees to tripping hazards. b) On or about 11/5/2015 - G Hall Rehabilitation Room, floor tiles around the drain were cracked and chipped exposing employees to tripping hazards. |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19101030 C01 IV |
Issuance Date |
2016-02-02 |
Abatement Due Date |
2016-03-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-03-07 |
Nr Instances |
1 |
Nr Exposed |
137 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1030(c)(1)(iv): The Exposure Control Plan was not reviewed and updated at least annually: On or about 11/5/2015 - Facility, the employer had not reviewed and updated the Exposure Control Plan for employees responsible for direct patient care who are potentially exposed to injuries from contaminated sharps. |
|
Citation ID |
01002B |
Citaton Type |
Other |
Standard Cited |
19101030 C01 IV B |
Issuance Date |
2016-02-02 |
Abatement Due Date |
2016-03-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-03-07 |
Nr Instances |
1 |
Nr Exposed |
137 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1030(c)(1)(iv)(B): The review and update of the exposure control plan did not document annually consideration and implementation of appropriate commercially available and effective safer medical devices designed to eliminate or minimize occupational exposure: a) On or about 11/05/2015 - Facility, the employer did not document annually consideration and implementation of appropriate commercially available and effective safer medical devices for employees responsible for direct patient care who are potentially exposed to injuries from contaminated sharps. |
|
Citation ID |
01002C |
Citaton Type |
Other |
Standard Cited |
19101030 C01 V |
Issuance Date |
2016-02-02 |
Abatement Due Date |
2016-03-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-03-07 |
Nr Instances |
1 |
Nr Exposed |
137 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1030(c)(1)(v): The employer, who is required to establish an Exposure Control Plan, did not solicit input from non-managerial employees responsible for direct patient care who are potentially exposed to injuries from contaminated sharps in the identification, evaluation and selection of effective engineering and work practice controls and did not document the solicitation in the Exposure Control Plan: a) On or about 11/05/2015 - Facility, the employer did not solicit and document solicitation of appropriate commercially available and effective safer medical devices for employees responsible for direct patient care who are potentially exposed to injuries from contaminated sharps. |
|
|
340936574
|
0418300
|
2015-09-22
|
915 STEWART AVENUE SE, ATTALLA, AL, 35954
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-09-22
|
Emphasis |
N: NURSING
|
Case Closed |
2015-11-20
|
Related Activity
Type |
Referral |
Activity Nr |
1021338 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2015-10-27 |
Abatement Due Date |
2015-11-23 |
Current Penalty |
3240.0 |
Initial Penalty |
5400.0 |
Final Order |
2015-11-25 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On or about July 26, 2015 - Hospital room C9, a lockout / tagout program had not been established for employees performing maintenance on equipment such as, but not limited to, the Gendron Maxi Rest Bariatric hospital bed, model #4748-W, Serial #036458-1-1-4. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2015-10-27 |
Current Penalty |
540.0 |
Initial Penalty |
900.0 |
Final Order |
2015-11-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours.: a) On or about 09/22/2015 - C.R. of Attalla, LLC dba Attalla Health & Rehab, 915 Stewart Avenue SE, Attalla, AL, an in-patient hospitalization that occurred on 07/26/2015 was not reported to OSHA within the required timeframe. |
|
|