Name: | T.L.Construction & Repairs Inc. |
Jurisdiction: | Alabama |
Legal type: | Domestic Corporation |
Status: | Exists |
Date of registration: | 28 Jan 2014 (11 years ago) |
Entity Number: | 000-295-945 |
Register Number: | 000295945 |
ZIP code: | 35983 |
County: | Cherokee |
Place of Formation: | Cherokee County |
Principal Address: | 4815 COUNTY RD 7LEESBURG, AL 35983 |
Registered Office Street Address: | 225 NORTH RIVER STCENTRE, AL 35960 |
Authorized Capital: | 3 @ $.01 PV |
Activities
CONSTRUCTION/CONTRACTOR SERVICES-REMODEL EXISTING RESIDENTIAL
Name | Role | Address |
---|---|---|
DUARTE, TRAVIS L | Director | 4815 COUNTY RD 7LEESBURG, AL 35983 |
Name | Role | Address |
---|---|---|
LEGALZOOM.COM INC | Incorporator | 101 N BRAND BLVD 10TH FLOORGLENDALE, CA 91203 |
Name | Role |
---|---|
DUARTE, ROBERT | Agent |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344182126 | 0418300 | 2019-07-25 | 1915 WEST MAIN STREET, CENTRE, AL, 35960 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-09-20 |
Current Penalty | 1193.5 |
Initial Penalty | 3410.0 |
Final Order | 2019-11-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets: (a) On or about 07/25/2018 - 1913 West Main Street, Centre, AL, employees working on the ground beneath employees working at upper levels were exposed to struck-by hazards. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-09-20 |
Current Penalty | 1193.5 |
Initial Penalty | 3410.0 |
Final Order | 2019-11-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: (a) On or about 07/25/2019 - 1913 West Main Street, Centre, AL, employees installing rock siding approximately 9 feet above the ground were not provided fall protection. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-09-27 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-11-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) On or about 07/25/2019 - 1913 West Main Street, Centre, AL, employees installing rock at approximately 9 feet above the ground did not recognize the fall hazard. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2019-09-10 |
Current Penalty | 1193.5 |
Initial Penalty | 3410.0 |
Final Order | 2019-11-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or about 07/25/2019 - 1913 West Main Street, Centre, AL, employees were using a Little Giant aluminum extension/folding ladder to gain access to an elevated area that was not extended as required. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19261060 A |
Issuance Date | 2019-09-10 |
Abatement Due Date | 2019-09-27 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-11-05 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: (a) On or about 07/25/2019 - 1913 West Main Street, Centre, AL, employees utilizing a Little Giant aluminum ladder to access a landing surface for the installation of rock siding did not use the ladder properly. |
Date of last update: 02 Aug 2024
Sources: Alabama Secretary of State