Search icon

Lewis Brothers Lumber Company, Inc.

Headquarter

Details

Name: Lewis Brothers Lumber Company, Inc.
Jurisdiction: Alabama
Legal type: Domestic Corporation
Status: Exists
Date of registration: 18 Dec 2008 (16 years ago)
Entity Number: 000-259-451
Register Number: 000259451
Historical Names: LBLC Holdings, Inc.
ZIP code: 35442
County: Pickens
Place of Formation: Pickens County
Principal Address: ALICEVILLE, AL
Registered Office Street Address: 1031 13TH ST NWALICEVILLE, AL 35442
Authorized Capital: $10,000

Activities FOREST PRODUCTS

Links between entities

Type Company Name Company Number State
Headquarter of Lewis Brothers Lumber Company, Inc., MISSISSIPPI 1042549 MISSISSIPPI

Agent

Name Role
LEWIS, JEFFREY BRYANT Agent

Incorporator

Name Role
LEWIS, DAVID MAJOR Incorporator
LEWIS, JEFFREY BRYANT Incorporator

Events

Event Date Event Type Old Value New Value
2009-01-09 Name Change LBLC Holdings, Inc. Lewis Brothers Lumber Company, Inc.

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347685356 0418300 2024-08-14 1031 13TH STREET NW, ALICEVILLE, AL, 35442
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-08-14
Emphasis N: AMPUTATE

Related Activity

Type Referral
Activity Nr 2197700
Safety Yes
345068837 0418300 2020-12-15 1031 13TH STREET NW, ALICEVILLE, AL, 35442
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2021-06-15
Case Closed 2022-07-19

Related Activity

Type Inspection
Activity Nr 1434934
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100146 F04
Issuance Date 2021-06-15
Abatement Due Date 2021-07-12
Current Penalty 8109.6
Initial Penalty 13516.0
Final Order 2021-07-08
Nr Instances 5
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(f)(4): The entry permit that documented compliance and authorized entry to a permit space did not identify the authorized entrants within the permit space by name or by such other means (for example, through the use of rosters or tracking): (a) On 2/12/2021 - Fuel House - Upper (a.k.a. Tee Pee), employees entering a confined space were not identified nor listed on the entry permit and exposed to hazardous energy and/or engulfment hazards from accumulated sawdust when they accessed the silo to grease fittings and change out a belt. (b) On 2/18/2021 - Fuel House - Upper (a.k.a. Tee Pee), employees entering a confined space were not identified nor listed on the entry permit and exposed to hazardous energy and/or engulfment hazards from accumulated sawdust when they accessed the silo to work on the agitator. (c) On 2/25/2021 - Fuel House - Upper (a.k.a. Tee Pee), employees entering a confined space were not identified nor listed on the entry permit and exposed to hazardous energy and/or engulfment hazards from accumulated sawdust when they accessed the silo to replace a broken belt. (d) On 3/5/2021 - Fuel House - Upper (a.k.a. Tee Pee), employees entering a confined space were not identified nor listed on the entry permit and exposed to hazardous energy and/or engulfment hazards from accumulated sawdust when they accessed the silo to replace a drive chain. (e) On 3/11/2021 - Fuel House - Upper (a.k.a. Tee Pee), employees entering a confined space were not identified nor listed on the entry permit and exposed to hazardous energy and/or engulfment hazards from accumulated sawdust when they accessed the silo to put on a belt.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100146 F05
Issuance Date 2021-06-15
Abatement Due Date 2021-07-12
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2021-07-08
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(f)(5):The entry permit that documented compliance and authorized entry to a permit space did not identify the personnel, by name, currently serving as attendants: (a) On 4/15/2021 - Fuel House - Upper (a.k.a. Tee Pee), employees entering confined spaces were exposed to hazardous energy and/or engulfment hazards from accumulated sawdust when they accessed the silo to conduct repairs and no attendant was identified for the entry.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100146 F07
Issuance Date 2021-06-15
Abatement Due Date 2021-07-12
Current Penalty 8109.6
Initial Penalty 13516.0
Final Order 2021-07-08
Nr Instances 11
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(f)(7): The entry permit that documented compliance and authorized entry to a permit space did not identify the hazards of the permit space to be entered: (a) On or about 5/4/2021, and at times prior - Fuel House - Upper (a.k.a. - Tee Pee), employees were exposed to engulfment hazards from bridged and normal sawdust because the employer had not identified this hazard nor listed it on the authorized entry permit for the space.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100146 J04
Issuance Date 2021-06-15
Abatement Due Date 2021-07-02
Current Penalty 8109.6
Initial Penalty 13516.0
Final Order 2021-07-08
Nr Instances 11
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(j)(4): The employer did not ensure that each entry supervisor verified that rescue services were available and that the means for summoning them were operable: (a) On 5/4/2021 - Fuel House - Upper (A.K.A. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not identify the rescue and emergency services to be summoned and the means for summoning those services. (b) On 4/15/2021 - Fuel House - Upper (A.K.A. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not identify the rescue and emergency services to be summoned and the means for summoning those services. (c) On 4/7/2021 - Fuel House - Upper (A.K.A. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not identify the rescue and emergency services to be summoned and the means for summoning those services. (d) On 3/11/2021 - Fuel House - Upper (A.K.A. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not identify the rescue and emergency services to be summoned and the means for summoning those services. (e) On 3/5/2021 - Fuel House - Upper (A.K.A. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not identify the rescue and emergency services to be summoned and the means for summoning those services. (f) On 3/1/2021 - Fuel House - Upper (A.K.A. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not identify the rescue and emergency services to be summoned and the means for summoning those services. (g) On 2/25/2021 - Fuel House - Upper (A.K.A. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not identify the rescue and emergency services to be summoned and the means for summoning those services. (h) On 2/18/2021 - Fuel House - Upper (A.K.A. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not identify the rescue and emergency services to be summoned and the means for summoning those services. (i) On 2/12/2021 - Fuel House - Upper (A.K.A. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not identify the rescue and emergency services to be summoned and the means for summoning those services. (j) On 2/4/2021 - Fuel House - Upper (A.K.A. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not identify the rescue and emergency services to be summoned and the means for summoning those services. (k) On 1/6/2021 - Fuel House - Upper (A.K.A. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not identify the rescue and emergency services to be summoned and the means for summoning those services.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100146 K02 IV
Issuance Date 2021-06-15
Abatement Due Date 2021-07-02
Current Penalty 8109.6
Initial Penalty 13516.0
Final Order 2021-07-08
Nr Instances 11
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(k)(2)(iv): The employer did not ensure that affected employees practice making permit space rescues at least once every 12 months, by means of simulated rescue operations in which they remove dummies, manikins, or actual persons from the actual permit spaces or from representative permit spaces: (a) On or about 12/15/2020 - Lewis Brothers Lumber Company, Aliceville, AL, ALERT Team Members had not practiced simulated or actual rescue operations in which they remove dummies or actual persons from the confined space while wearing appropriate protective equipment.
Citation ID 02001
Citaton Type Serious
Standard Cited 19100146 D06
Issuance Date 2021-06-15
Abatement Due Date 2021-07-12
Current Penalty 8109.6
Initial Penalty 27033.0
Final Order 2021-07-08
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(d)(6):The employer did not provide at least one attendant outside the permit space into which entry was authorized for the duration of entry operations: (a) On or about 04/15/2021 - Fuel House (a.k.a. Tee Pee), employees were exposed to hazardous energy and engulfment hazards because the employer did not provide at least one attendant outside the Fuel House (a.k.a. Tee Pee) for the duration of entry operations. Lewis Brothers Lumber Company, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.146(d)(6), which was contained in OSHA inspection number 1434934, citation number 1, item number 2 and was affirmed as a final order on 04/15/2020, with respect to a workplace located at 1031 13th Street NW, Aliceville, AL 35442.
Citation ID 02002
Citaton Type Repeat
Standard Cited 19100146 D09
Issuance Date 2021-06-15
Abatement Due Date 2021-07-02
Current Penalty 16219.8
Initial Penalty 27033.0
Final Order 2021-07-08
Nr Instances 11
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(d)(9): The employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and/or for preventing unauthorized entry: (a) On or about 5/4/2021, and at times back to 1/6/2021 - Fuel House - Upper (a.k.a. Tee Pee), employees entering the silo were exposed to hazardous energy and engulfment hazards due to the accumulation of sawdust and adequate measures such as, but not limited to the employer not identifying the Rescue and Emergency Services or how to contact the Rescue and Emergency Services for entries dated between 1/6/2021 to 5/4/2021. Lewis Brothers Lumber Company, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.146(d)(9), which was contained in OSHA inspection number 1434934, citation number 1, item number 3 and was affirmed as a final order on 4/15/2020, with respect to a workplace located at 1031 13th Street NW, Aliceville, AL 35442.
344349345 0418300 2019-10-01 1031 13TH STREET NW, ALICEVILLE, AL, 35442
Inspection Type Fat/Cat
Scope Partial
Safety/Health Safety
Close Conference 2020-03-24
Emphasis N: SVEP
Case Closed 2020-08-11

Related Activity

Type Accident
Activity Nr 1503489

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19100146 D03 VI
Issuance Date 2020-03-26
Abatement Due Date 2020-07-17
Current Penalty 5000.0
Initial Penalty 10409.0
Final Order 2020-04-15
Nr Instances 2
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(d)(3)(vi): The employer did not verify that conditions in the permit space are acceptable for entry throughout the duration of an authorized entry: (a) On or about 03/01/2020 and at times earlier - Fuel House (a.k.a. Teepee), the employer did not verify that conditions in the permit required space such as working surface stability and energy isolation were acceptable for entry throughout the duration of the authorized entry, exposing employees entering the silo to engulfment, fall, amputation, and caught-in hazards.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100146 D06
Issuance Date 2020-03-26
Abatement Due Date 2020-07-17
Current Penalty 7286.3
Initial Penalty 10409.0
Final Order 2020-04-15
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(d)(6): The employer did not provide at least one attendant outside the permit space into which entry was authorized for the duration of entry operations: (a) On or about 03/01/2020 and at times earlier - Fuel House (a.k.a. Teepee), the employer did not provide at least one attendant outside the silo into which entry was authorized for the duration of entry operations, exposing employees entering the silo to engulfment, fall, amputation, and caught-in hazards.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100146 D09
Issuance Date 2020-03-26
Abatement Due Date 2020-07-17
Current Penalty 7286.3
Initial Penalty 12145.0
Final Order 2020-04-15
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(d)(9): The employer did not develop and implement procedures for summoning rescue and emergency services, for rescuing entrants from permit spaces, for providing necessary emergency services to rescued employees, and/or for preventing unauthorized entry: (a) On or about 09/27/2019 - Fuel House (a.k.a. Teepee), employees entering the silo were exposed to an engulfment hazard due to the accumulation of sawdust and adequate measures were not implemented to ensure timely rescue when emergency situations occurred.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100146 G01
Issuance Date 2020-03-26
Abatement Due Date 2020-07-17
Current Penalty 7286.3
Initial Penalty 10409.0
Final Order 2020-04-15
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146: (a) On or about 03/01/2020 and at times earlier - Fuel House (a.k.a. Teepee), employees who entered the silo to perform tasks such as, but not limited to, breaking up bridged sawdust and/or to adjusting chains on the Agitator were not trained to recognize engulfment, fall, caught-in and amputation hazards.
Citation ID 01005A
Citaton Type Serious
Standard Cited 19100147 C07 I A
Issuance Date 2020-03-26
Abatement Due Date 2020-07-17
Current Penalty 7286.3
Initial Penalty 10409.0
Final Order 2020-04-15
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: (a) On or about 09/27/2019 - Fuel House (a.k.a. Teepee), affected employees who were not trained as authorized employees, performed the duties of authorized employees when entering the silo to perform activities such as greasing and adjusting chains on the Agitator resulting in exposure to caught-in and amputation hazards.
Citation ID 01005B
Citaton Type Serious
Standard Cited 19100147 D04 I
Issuance Date 2020-03-26
Abatement Due Date 2020-07-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-04-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) On or about 09/27/2019 - Fuel House (a.k.a. Teepee), Boiler operators did not affix a lock on the three main electrical disconnects on the exterior of the silo to secure hazardous energy, exposing employees to caught-in and amputation hazards.
Citation ID 01006
Citaton Type Serious
Standard Cited 19100265 C04 IV
Issuance Date 2020-03-26
Abatement Due Date 2020-07-17
Current Penalty 7286.3
Initial Penalty 10409.0
Final Order 2020-04-15
Nr Instances 2
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.265(c)(4)(iv): Elevated walkways(s) and runway(s), 4 feet or more from floor level, were not provided with a standard railing: (a) On or about 09/27/2019 - Fuel House (a.k.a. Teepee), employees on the platform used to access the silo were exposed to a fall hazard of approximately 12 feet due to one side of the platform missing the standard railing.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19100146 D01
Issuance Date 2020-03-26
Abatement Due Date 2020-07-17
Current Penalty 134937.0
Initial Penalty 134937.0
Final Order 2020-04-15
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(d)(1): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not implement the measures necessary to prevent unauthorized entry: (a) On or about 09/27/2019 - Fuel House (a.k.a. Teepee), the employer permitted unauthorized employees to enter the silo to perform tasks such as breaking up bridged sawdust built up on the interior surfaces and/or to adjust chains on the Agitator, exposing employees to engulfment, fall, caught-in, and amputation hazards.
Citation ID 03001
Citaton Type Other
Standard Cited 19100146 C02
Issuance Date 2020-03-26
Abatement Due Date 2020-07-17
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-04-15
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of, and the danger posed by the permit spaces: (a) On or about 09/27/2019 - Fuel House (a.k.a. Teepee), signs were not posted at the entrance to the silo identifying the area as a permit-required confined space.
341657492 0418300 2016-07-27 1031 13TH STREET NW, ALICEVILLE, AL, 35442
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2016-07-27
Emphasis N: DUSTEXPL
Case Closed 2016-11-29

Related Activity

Type Referral
Activity Nr 1115656
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C07 I B
Issuance Date 2016-11-01
Abatement Due Date 2016-11-14
Current Penalty 6000.0
Initial Penalty 8177.0
Final Order 2016-11-16
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: (a) On or about 07/21/2016 - Flooring Mill, Rough Chop Saw Area, saw operators had not been instructed in the proper steps to take when removing jams from the cutting areas of the chop saw.
Citation ID 02001
Citaton Type Other
Standard Cited 19100147 C07 I B
Issuance Date 2016-11-01
Abatement Due Date 2016-11-14
Current Penalty 0.0
Initial Penalty 765.0
Final Order 2016-11-16
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(B): Each affected employee shall be instructed in the purpose and use of the energy control procedure: (a) On or about 07/21/2016 - Flooring Mill, Rough Chop Saw Area, saw operators had not been instructed in the proper steps to take when removing jams from the cutting areas of the chop saw.
334513744 0418300 2012-05-31 1031 13TH STREET NW, ALICEVILLE, AL, 35442
Inspection Type Planned
Scope Partial
Safety/Health Health
Close Conference 2012-06-05
Emphasis L: HINOISE, L: FORKLIFT, P: HINOISE, L: EISAOF, L: EISAX
Case Closed 2012-10-23

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2012-08-21
Current Penalty 1785.0
Initial Penalty 2975.0
Final Order 2012-09-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: a) On or about 5/31/12 - Plant area, the Taylor Forklift #4D, Model #Y-20-BWO, SN# S-3S-0519 was operated by an employee and a seat belt was not provided.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100178 P01
Issuance Date 2012-08-21
Current Penalty 1428.0
Initial Penalty 2380.0
Final Order 2012-09-15
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been of service until restored to safe operating condition(s): (a) On or or about 5/31/12 - Plant area, the Taylor industrial powered truck #F6, Model# TEB-250M, SN#S-02-22628, was operated with an inoperable horn. (b) On or or about 5/31/12 - Plant area, the Taylor industrial powered truck #7G, Model# TEB-200S, SN#S-H1-23087, was operated with an inoperable horn. c) On or about 5/31/12 - Plant area, the Taylor industrial powered truck #4D, Model# Y-20-BWO, SN# 5369519, was operated with an inoperable horn.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2012-08-21
Abatement Due Date 2012-08-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-09-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) On or about 5/31/12 - Plant Area, an employee was operating a Taylor powered industrial truck #7G, Model #TE-200S/SN# S-H1-2307, without completing training and evaluation.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100253 B04 III
Issuance Date 2012-08-21
Current Penalty 1071.0
Initial Penalty 1785.0
Final Order 2012-09-15
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) On or about 6/2-6/4/12 - South side at ground floor of the sawmill building near the shop entrance, three oxygen cylinders and one acetylene cylinder were chiained next to each other.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100219 F03
Issuance Date 2012-08-21
Abatement Due Date 2012-08-28
Current Penalty 1428.0
Initial Penalty 2380.0
Final Order 2012-09-15
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven feet or less above floors or platforms were not enclosed: (a) On or prior to 6/5/12 - Grading shed, the electrically powered conveyor chain near the operator was nto enclosed.
304711856 0418300 2001-11-19 1031 13TH STREET, ALICEVILLE, AL, 35442
Inspection Type Accident
Scope NoInspection
Safety/Health Safety
Close Conference 2001-11-19
Case Closed 2001-11-20

Related Activity

Type Accident
Activity Nr 101271435

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
9493637004 2020-04-09 0459 PPP 1031 13TH ST, ALICEVILLE, AL, 35442-1512
Loan Status Date 2020-12-18
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 949700
Loan Approval Amount (current) 949700
Undisbursed Amount 0
Franchise Name -
Lender Location ID 39535
Servicing Lender Name BankFirst Financial Services
Servicing Lender Address 900 Main St, COLUMBUS, MS, 39701-4721
Rural or Urban Indicator R
Hubzone N
LMI Y
Business Age Description Existing or more than 2 years old
Project Address ALICEVILLE, PICKENS, AL, 35442-1512
Project Congressional District AL-07
Number of Employees 120
NAICS code 321113
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 39535
Originating Lender Name BankFirst Financial Services
Originating Lender Address COLUMBUS, MS
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 955741.15
Forgiveness Paid Date 2020-11-27

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
274950 Interstate 2024-11-25 78000 2023 6 6 Private(Property)
Legal Name LEWIS BROTHERS LUMBER COMPANY INC
DBA Name -
Physical Address 1031 13TH ST NW, ALICEVILLE, AL, 35442, US
Mailing Address 1031 13TH ST NW, ALICEVILLE, AL, 35442, US
Phone (205) 373-2496
Fax (205) 373-2122
E-mail SANDY@LEWISBROTHERSLUMBER.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 2
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 10
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 2
Vehicle Maintenance BASIC Roadside Performance measure value 11
Total Number of Vehicle Inspections for the measurement period 1
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 2
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 2
Number of inspections with at least one Vehicle Maintenance BASIC violation 1
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Inspections

Unique report number of the inspection JBXV003627
State abbreviation that indicates the state the inspector is from AL
The date of the inspection 2024-02-09
ID that indicates the level of inspection Driver-Only
State abbreviation that indicates where the inspection occurred AL
Time weight of the inspection 2
Number of Out-Of-Service violations related to Driver 1
Number of Out-Of-Service violations related to vehicle 0
Number of violations related to Hazardous Materials 0
Total number of Out-Of-Service violations 1
Total number of Out-Of-Service violations related to Hazardous Materials 0
Description of the type of the main unit TRUCK TRACTOR
Description of the make of the main unit PTRB
License plate of the main unit 1194925
License state of the main unit AL
Vehicle Identification Number of the main unit 1XPXD49X2ND811288
Description of the type of the secondary unit SEMI-TRAILER
Description of the make of the secondary unit PERL
License plate of the secondary unit A101585
License state of the secondary unit AL
Vehicle Identification Number of the secondary unit 1PLE04523FPE59128
Unsafe Driving BASIC inspection Y
Hours-of-Service Compliance BASIC inspection Y
Driver Fitness BASIC inspection Y
Controlled Substances/Alcohol BASIC inspection Y
Total number of BASIC violations 1
Number of Unsafe Driving BASIC violations 0
Number of Hours-of-Service Compliance BASIC violations 0
Number of Driver Fitness BASIC violations 1
Number of Controlled Substances/Alcohol BASIC violations 0
Number of Vehicle Maintenance BASIC violations 0
Number of Hazardous Materials Compliance BASIC violations 0
Unique report number of the inspection RCCV001017
State abbreviation that indicates the state the inspector is from AL
The date of the inspection 2023-08-28
ID that indicates the level of inspection Walk-around
State abbreviation that indicates where the inspection occurred AL
Time weight of the inspection 1
Number of Out-Of-Service violations related to Driver 1
Number of Out-Of-Service violations related to vehicle 0
Number of violations related to Hazardous Materials 0
Total number of Out-Of-Service violations 1
Total number of Out-Of-Service violations related to Hazardous Materials 0
Description of the type of the main unit TRUCK TRACTOR
Description of the make of the main unit PTRB
License plate of the main unit 1194925
License state of the main unit AL
Vehicle Identification Number of the main unit 1XPXD49X2ND811288
Description of the type of the secondary unit SEMI-TRAILER
Description of the make of the secondary unit PERL
License plate of the secondary unit A101545
License state of the secondary unit AL
Vehicle Identification Number of the secondary unit 1PLE04224FPD59088
Unsafe Driving BASIC inspection Y
Hours-of-Service Compliance BASIC inspection Y
Driver Fitness BASIC inspection Y
Controlled Substances/Alcohol BASIC inspection Y
Vehicle Maintenance BASIC inspection Y
Total number of BASIC violations 4
Number of Unsafe Driving BASIC violations 0
Number of Hours-of-Service Compliance BASIC violations 0
Number of Driver Fitness BASIC violations 1
Number of Controlled Substances/Alcohol BASIC violations 0
Number of Vehicle Maintenance BASIC violations 3
Number of Hazardous Materials Compliance BASIC violations 0

Violations

The date of the inspection 2023-08-28
Code of the violation 38323A2
Name of the BASIC Driver Fitness
The violation is identified as Out-Of-Service violation Y
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 2
The severity weight that is assigned to a violation 8
The time weight that is assigned to a violation 1
The description of a violation Operating a CMV without a CDL
The description of the violation group License-related: High
The unit a violation is cited against Driver
The date of the inspection 2023-08-28
Code of the violation 3939
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 2
The time weight that is assigned to a violation 1
The description of a violation Inoperable Required Lamp
The description of the violation group Clearance Identification Lamps/Other
The unit a violation is cited against Vehicle main unit
The date of the inspection 2023-08-28
Code of the violation 39378
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 1
The time weight that is assigned to a violation 1
The description of a violation Wipers - Inoperative / missing / damaged wipers
The description of the violation group Windshield/ Glass/ Markings
The unit a violation is cited against Vehicle main unit
The date of the inspection 2023-08-28
Code of the violation 39375A4
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 8
The time weight that is assigned to a violation 1
The description of a violation Tire-cut exposing ply and/or belt material
The description of the violation group Tires
The unit a violation is cited against Vehicle main unit

Date of last update: 02 Aug 2024

Sources: Alabama Secretary of State