Search icon

Adient Clanton Inc.

Details

Name: Adient Clanton Inc.
Jurisdiction: Alabama
Legal type: Domestic Corporation
Status: Exists
Date of registration: 25 May 1999 (26 years ago)
Entity Number: 000-203-391
Register Number: 000203391
Historical Names: CRH North America, Inc.
Johnson Controls Clanton, Inc.
ZIP code: 36104
County: Montgomery
Place of Formation: Montgomery County
Registered Office Street Address: 2 NORTH JACKSON STREET SUITE 605MONTGOMERY, AL 36104
Authorized Capital: 26,754 @ $1 PV

Activities MANUFACTURE/ASSEMBLE COMPONENT PARTS USED IN AUTOMOBILE INDUSTRY

Director

Name Role
MCDONALD, R BRUCE Director
POLEN, VICTOR A Director
OKARMA, JEROME D Director

Incorporator

Name Role
HOUSTON, R S I Incorporator

Agent

Name Role Address
CT CORPORATION SYSTEM Agent 6190 POWERS FERRY RD STE 600ATLANTA, GA 30339

Events

Event Date Event Type Old Value New Value
2016-09-16 Name Change Johnson Controls Clanton, Inc. Adient Clanton Inc.
2014-10-15 Name Change CRH North America, Inc. Johnson Controls Clanton, Inc.
2012-07-24 Capital Change $1,000 Authorized --- Paid In 26,754 @ $1 PV Authorized undefined Paid In

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342534112 0418600 2017-08-08 2541 7TH AVE. SOUTH, CLANTON, AL, 35046
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2017-08-09
Emphasis L: FORKLIFT, L: AUTOSUP, N: AMPUTATE
Case Closed 2018-06-20

Related Activity

Type Accident
Activity Nr 1250009
Type Complaint
Activity Nr 1266837
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2018-01-23
Abatement Due Date 2018-02-16
Current Penalty 11500.0
Initial Penalty 12934.0
Final Order 2018-02-14
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) At Laser Weld Machine: On or about August 8, 2017 and at times prior; employees were exposed to struck-by hazards in that the employer failed to ensure employees utilized the hazardous energy control procedures when employees were engaged in servicing and maintenance activities, including but not limited to, removing parts and making repairs to the laser weld machine.
Citation ID 01002
Citaton Type Other
Standard Cited 19100147 C04 II
Issuance Date 2018-01-23
Abatement Due Date 2018-02-16
Current Penalty 10000.0
Initial Penalty 10163.0
Final Order 2018-02-14
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) At Upper Rail Line: On or about September 27, 2017 and at times prior; the employer exposed his employees to hazardous energy in that employees were allowed to work on and around equipment that was locked out using energy control procedures that did not contain the required elements directed by the standard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2018-01-23
Abatement Due Date 2018-02-16
Current Penalty 0.0
Initial Penalty 12934.0
Final Order 2018-02-14
Nr Instances 2
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) At Laser Weld Machine: On or about August 8, 2017 and at times prior; employees were exposed to struck-by and electrocution hazards in that the employer failed to conduct a periodic inspection of the machine specific procedures for lock out tag out. b) At FKK Main Line: On or about September 27, 2017 and at times prior; employees were exposed to struck-by and electrocution hazards in that the employer failed to conduct a periodic inspection of the machine specific procedures for lock out tag out.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100147 C07 I A
Issuance Date 2018-01-23
Abatement Due Date 2018-02-16
Current Penalty 11500.0
Initial Penalty 12934.0
Final Order 2018-02-14
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: a) At Laser Weld Machine: On or about August 8, 2017 and at times prior; the employer allowed the first shift team leader to perform routine maintenance on the Laser Welder without first ensuring the employee was trained as an authorized employee exposing the employee struck-by hazards and electrical hazards.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2018-01-23
Abatement Due Date 2018-02-16
Current Penalty 6000.0
Initial Penalty 6911.0
Final Order 2018-02-14
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) At the FKK Mail Line: On or about August September 17, 2017 and at times prior; the employer allowed employees to perform routine maintenance on station 6 without first ensuring guards were in place exposing employees to struck-by hazards. An employee performing routine maintenance on station 6 was struck-by the machine in an area that was not guarded.
316087139 0418600 2011-11-16 2541 7TH ST SOUTH, CLANTON, AL, 35046
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2011-11-17
Emphasis N: SSTARG11, N: AMPUTATE, L: FORKLIFT, S: POWERED IND VEHICLE, S: NOISE, S: AMPUTATIONS
Case Closed 2012-04-24

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100022 A01
Issuance Date 2012-03-16
Abatement Due Date 2012-03-21
Current Penalty 3000.0
Initial Penalty 3000.0
Nr Instances 1
Nr Exposed 1
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19100146 E01
Issuance Date 2012-03-16
Abatement Due Date 2012-03-28
Current Penalty 5000.0
Initial Penalty 7000.0
Nr Instances 2
Nr Exposed 2
Gravity 10
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2012-03-16
Abatement Due Date 2012-03-28
Current Penalty 5000.0
Initial Penalty 7000.0
Nr Instances 1
Nr Exposed 1
Gravity 10
Citation ID 01004
Citaton Type Serious
Standard Cited 19100335 A01 I
Issuance Date 2012-03-16
Abatement Due Date 2012-04-04
Current Penalty 5000.0
Initial Penalty 7000.0
Nr Instances 1
Nr Exposed 2
Gravity 10
308467422 0418600 2005-02-01 2541 7TH ST., SOUTH, CLANTON, AL, 35045
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2005-02-02
Case Closed 2005-06-22

Related Activity

Type Complaint
Activity Nr 203134176
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100146 C01
Issuance Date 2005-04-07
Abatement Due Date 2005-04-19
Current Penalty 4500.0
Initial Penalty 4500.0
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 10
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100146 C04
Issuance Date 2005-04-07
Abatement Due Date 2005-04-19
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 10
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100146 E01
Issuance Date 2005-04-07
Abatement Due Date 2005-04-19
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 10
Citation ID 01002
Citaton Type Serious
Standard Cited 19100146 G01
Issuance Date 2005-04-07
Abatement Due Date 2005-04-19
Current Penalty 4500.0
Initial Penalty 4500.0
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 10
Citation ID 01003
Citaton Type Serious
Standard Cited 19100146 D09
Issuance Date 2005-04-07
Abatement Due Date 2005-06-17
Current Penalty 4500.0
Initial Penalty 4500.0
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 10
Citation ID 01004A
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2005-04-07
Abatement Due Date 2005-06-17
Current Penalty 4500.0
Initial Penalty 4500.0
Nr Instances 6
Nr Exposed 2
Gravity 10
Citation ID 01004B
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2005-04-07
Abatement Due Date 2005-06-17
Nr Instances 6
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 10
Citation ID 01005
Citaton Type Serious
Standard Cited 19100151 C
Issuance Date 2005-04-07
Abatement Due Date 2005-04-13
Current Penalty 4500.0
Initial Penalty 4500.0
Nr Instances 3
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 10
Citation ID 02001
Citaton Type Other
Standard Cited 19100095 K02
Issuance Date 2005-04-07
Abatement Due Date 2005-04-26
Nr Instances 5
Nr Exposed 5
Gravity 01
Citation ID 02002
Citaton Type Other
Standard Cited 19101030 F02 I
Issuance Date 2005-04-07
Abatement Due Date 2005-05-27
Nr Instances 1
Nr Exposed 2
Gravity 01

Date of last update: 01 Aug 2024

Sources: Alabama Secretary of State