Search icon

Gates Builders, Inc.

Headquarter

Details

Name: Gates Builders, Inc.
Jurisdiction: Alabama
Legal type: Domestic Corporation
Status: Exists
Date of registration: 16 Jan 1998 (27 years ago)
Entity Number: 000-192-611
Register Number: 000192611
ZIP code: 35442
County: Pickens
Place of Formation: Pickens County
Principal Address: ALICEVILLE, AL
Registered Office Street Address: HWY 14ALICEVILLE, AL 35442
Authorized Capital: $5,000
Paid Share Capital: $1,000

Activities CONSTRUCTION AND CONTRACTOR BUSINESS

Links between entities

Type Company Name Company Number State
Headquarter of Gates Builders, Inc., MISSISSIPPI 699546 MISSISSIPPI

Agent

Name Role
GATES, KENNETH J Agent

Incorporator

Name Role
GATES, KENNETH J Incorporator

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339983488 0418600 2014-10-02 400 PLANTATION DR RESORT CONFERENCE CENTER, GULF SHORES, AL, 36542
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-10-02
Emphasis L: FALL, P: FALL
Case Closed 2014-11-25

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C01 II
Issuance Date 2014-10-31
Current Penalty 1395.0
Initial Penalty 1700.0
Final Order 2014-11-25
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide: a) At Gulf Shores Plantation Condos: On or about October 2, 2014 and at times prior; the employees were exposed to a fall hazard of 27 feet to the ground below while working and walking on the third and forth levels of the scaffolding system. Ties that had been in place were taken down to apply wrap around the building and the scaffold was not secured back to the building.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2014-10-31
Current Penalty 1395.0
Initial Penalty 2000.0
Final Order 2014-11-25
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) At Gulf Shores Plantation Condos Scaffold Section 8 and 9: On or about October 2, 2014; the employer allowed his employees to climb down the sides of a four buck high scaffold exposing them to a fall hazard of 27 feet to ground below. b) At Gulf Shores Plantation Condos Scaffold Section 7: On or about October 2, 2014; the employer allowed his employees to climb up the sides of a scaffold to reach the fourth buck work platform exposing them to a fall hazard of 27 feet to ground below.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2014-10-31
Current Penalty 1395.0
Initial Penalty 2800.0
Final Order 2014-11-25
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) At Gulf Shores Plantation Condos: On October 2, 2014 and at times prior; the employer failed to ensure scaffolding used by his employees was inspected by a competent person prior to employees working from scaffold exposing them to fall hazards.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2014-10-31
Current Penalty 1395.0
Initial Penalty 2800.0
Final Order 2014-11-25
Nr Instances 5
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) At Scaffold Section 5: On or about October 2, 2014 and at times prior; the employer exposed his employees to a fall hazard of 27 feet to ground below in that employees were allowed to work from the fourth level of a five buck scaffold without fall protection such as but no limited to guardrail system, person fall arrest systems, of safety net systems. b) At Scaffold Section 8: On or about October 2, 2014 and at times prior; the employer exposed his employees to a fall hazard of 27 feet to ground below in that employees were allowed to work from the fourth level of a four buck scaffold without fall protection such as but no limited to guardrail system, person fall arrest systems, of safety net systems. c) At Scaffold Section 10: On or about October 2, 2014 and at times prior; the employer exposed his employees to a fall hazard of 13.6 feet to ground below in that employees were allowed to work from the third level of a five buck scaffold without fall protection such as but no limited to guardrail system, person fall arrest systems, of safety net systems. d) At Scaffold Section 4 and 5: On or about October 2, 2014 and at times prior; the employer exposed his employees to a fall hazard of 27 feet to ground below in that employees were allowed to walk between the sections and did not have fall protection such as but no limited to guardrail system, person fall arrest systems, of safety net systems. e) At Scaffold Section 7 and 8: On or about October 2, 2014 and at times prior; the employer exposed his employees to a fall hazard of 27 feet to ground below in that employees were allowed to walk between the sections and did not have fall protection such as but no limited to guardrail system, person fall arrest systems, of safety net systems.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19260451 G04 IV
Issuance Date 2014-10-31
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-11-25
Nr Instances 2
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface: a) At Scaffold Section 5: On or about October 2, 2014 and at times prior; the employer failed to ensure midrails were installed on the fourth buck on a scaffold platform where employees were working exposing them to a fall hazard of 27 feet to the ground below. b) At Scaffold Section 10: On or about October 2, 2014 and at times prior; the employer failed to ensure midrails were installed on the third buck on a scaffold platform where employees were working exposing them to a fall hazard of 21.1 feet to the ground below.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
8556577101 2020-04-15 0459 PPP 9153 Hard Dr, FOLEY, AL, 36535-3778
Loan Status Date 2022-03-26
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 115497
Loan Approval Amount (current) 115497
Undisbursed Amount 0
Franchise Name -
Lender Location ID 450245
Servicing Lender Name First Cahawba Bank
Servicing Lender Address 2610 Citizens Pkwy, SELMA, AL, 36701-4037
Rural or Urban Indicator R
Hubzone Y
LMI Y
Business Age Description Existing or more than 2 years old
Project Address FOLEY, BALDWIN, AL, 36535-3778
Project Congressional District AL-01
Number of Employees 13
NAICS code 236220
Borrower Race White
Borrower Ethnicity Not Hispanic or Latino
Business Type Subchapter S Corporation
Originating Lender ID 450245
Originating Lender Name First Cahawba Bank
Originating Lender Address SELMA, AL
Gender Male Owned
Veteran Unanswered
Forgiveness Amount 116687.26
Forgiveness Paid Date 2021-04-22

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
1955169 Intrastate Non-Hazmat 2024-09-03 8000 2023 1 1 Private(Property)
Legal Name GATES BUILDERS INC
DBA Name -
Physical Address 9153 HARD DRIVE, FOLEY, AL, 36535, US
Mailing Address PO BOX 6247, GULF SHORES, AL, 36547, US
Phone (251) 981-9540
Fax (251) 981-9542
E-mail DAWNGATES@GATESBUILDERS.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 01 Aug 2024

Sources: Alabama Secretary of State