OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339626764 0418300 2014-03-05 2319 COGSWELL AVE., PELL CITY, AL, 35125
Inspection Type Prog Other
Scope Partial
Safety/Health Safety
Close Conference 2014-03-10
Emphasis L: FALL, P: FALL
Case Closed 2015-04-01

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100178 L01 I
Issuance Date 2014-08-15
Abatement Due Date 2014-09-04
Current Penalty 0.0
Initial Penalty 1600.0
Contest Date 2014-08-28
Final Order 2015-01-16
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l) and as referenced by the note contained in 1926.602(d): (a) On or about 3/5/14 - at 2319 Cogswell Ave., Pell City, AL, the employer did not ensure and certify that each powered industrial truck operator was competent to operate the Terex Square Shooter SS-842 Telehandler safely. (b) On or about 3/10/14 - at 2319 Cogswell Ave., Pell City, AL, the employer did not ensure and certify that each powered industrial truck operator was competent to operate the Terex Square Shooter SS-842 Telehandler safely.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260150 A04
Issuance Date 2014-08-15
Abatement Due Date 2014-08-25
Current Penalty 0.0
Initial Penalty 1200.0
Contest Date 2014-08-28
Final Order 2015-01-16
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.150(a)(4): All firefighting equipment was not inspected and maintained in operating condition. (a) On or about 3/5/14 - at 2319 Cogswell Ave., Pell City, AL, the Pyro-Chem ABC fire extinguisher located on the Terex Square Shooter SS-842 Telehandler was not maintained.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 C02 IV
Issuance Date 2014-08-15
Abatement Due Date 2014-09-11
Current Penalty 2000.0
Initial Penalty 2000.0
Contest Date 2014-08-28
Final Order 2015-01-16
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms when they were not specifically designed by the manufacturer for such use: (a) On or about 3/5/14 - at 2319 Cogswell Ave., Pell City, AL, the elevated scaffold platform supported by the Terex Square Shooter SS-842 Telehandler was not specifically designed by the manufacturer for such use and certification was not provided from a certified professional engineer documenting that the forklift is able to safely lift and support the personnel work platform. (b) On or about 3/10/14 - at 2319 Cogswell Ave., Pell City, AL, the elevated scaffold platform supported by the Terex Square Shooter SS-842 Telehandler was not specifically designed by the manufacturer for such use and certification was not provided from a certified professional engineer documenting that the forklift is able to safely lift and support the personnel work platform.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260502 D16 III
Issuance Date 2014-08-15
Abatement Due Date 2014-08-21
Current Penalty 1600.0
Initial Penalty 1600.0
Contest Date 2014-08-28
Final Order 2015-01-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: (a) On or about 3/10/14 - at 2319 Cogswell Ave., Pell City, AL, an employee's personal fall arrest system was not rigged to protect the employee from falling more than 6 feet.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2014-08-15
Abatement Due Date 2014-08-21
Current Penalty 0.0
Initial Penalty 2000.0
Contest Date 2014-08-28
Final Order 2015-01-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who was on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems: (a) On or about 3/5/14 - at 2319 Cogswell Ave., Pell City, AL, an employee was not protected from falling about 18.5 feet.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260761 B
Issuance Date 2014-08-15
Abatement Due Date 2014-09-04
Current Penalty 0.0
Initial Penalty 2800.0
Contest Date 2014-08-28
Final Order 2015-01-16
Nr Instances 2
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.761(b): The employer did not train each employee exposed to a fall hazard in accordance with the requirements of 29 CFR 1926.761: (a) On or about 3/5/14 - at 2319 Cogswell Ave., Pell City, AL, the employer did not train each employee exposed to a fall hazard in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. (b) On or about 3/10/14 - at 2319 Cogswell Ave., Pell City, AL, the employer did not train each employee exposed to a fall hazard in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.
314425927 0418300 2010-06-10 751 US HIGHWAY 431, BOAZ, AL, 35957
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2010-06-10
Emphasis S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT, L: FALL
Case Closed 2010-07-12

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2010-06-17
Abatement Due Date 2010-06-22
Current Penalty 450.0
Initial Penalty 600.0
Nr Instances 1
Nr Exposed 1
Gravity 02
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261060 A01 III
Issuance Date 2010-06-17
Abatement Due Date 2010-06-25
Nr Instances 1
Nr Exposed 1
Gravity 02

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
5690497207 2020-04-27 0459 PPP 3997 POPE AVE, STEELE, AL, 35987-2930
Loan Status Date 2021-01-14
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 34600
Loan Approval Amount (current) 34600
Undisbursed Amount 0
Franchise Name -
Lender Location ID 112423
Servicing Lender Name Peoples Independent Bank
Servicing Lender Address 121 Billy B Dyar Blvd, BOAZ, AL, 35957
Rural or Urban Indicator R
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address STEELE, SAINT CLAIR, AL, 35987-2930
Project Congressional District AL-03
Number of Employees 6
NAICS code 236220
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 112423
Originating Lender Name Peoples Independent Bank
Originating Lender Address BOAZ, AL
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 34829.71
Forgiveness Paid Date 2020-12-28

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
1523809 Interstate 2024-10-25 4000 2024 3 3 Private(Property)
Legal Name AAA METAL BUILDINGS INC
DBA Name AAA STEEL BUILDINGS
Physical Address 3997 POPE AVE, STEELE, AL, 35987, US
Mailing Address 3997 POPE AVE, STEELE, AL, 35987, US
Phone (256) 538-5416
Fax (256) 538-3306
E-mail AAABLDGS@PEOPLEPC.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 01 Aug 2024