347215840
|
0418300
|
2024-01-17
|
1701 BOONE BOULEVARD, NORTHPORT, AL, 35476
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-01-17
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2024-04-05
|
Related Activity
Type |
Referral |
Activity Nr |
2118245 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2024-02-15 |
Current Penalty |
16131.0 |
Initial Penalty |
16131.0 |
Final Order |
2024-03-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 01/08/2024 - 3X Tube Mill, Guide N Welder, employees were exposed to caught-in hazards when the pinch-point between the entry-side guide and the steel strip edge was not guarded. |
|
|
346729486
|
0418300
|
2023-05-24
|
1701 BOONE BOULEVARD, NORTHPORT, AL, 35476
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-05-25
|
Case Closed |
2023-07-24
|
Related Activity
Type |
Referral |
Activity Nr |
2032636 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2023-06-15 |
Abatement Due Date |
2023-07-13 |
Current Penalty |
36834.0 |
Initial Penalty |
73667.0 |
Final Order |
2023-07-14 |
Nr Instances |
3 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 05/03/2023 and at times prior to - 5K-TM-17 Tube Mill, employees were exposed to caught-in hazards when the pinch-point between the steel tube and #14 sidepass roller was not guarded. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2023-06-15 |
Current Penalty |
6139.0 |
Initial Penalty |
12278.0 |
Final Order |
2023-07-14 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours: (a) On or about 05/03/2023 - 1701 Boone Boulevard, Northport, AL, the employer did not report to OSHA within (24) hours a work-related amputation. The employer reported the amputation on 05/18/2023. |
|
|
345859524
|
0418300
|
2022-03-24
|
1701 BOONE BLVD., NORTHPORT, AL, 35476
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-09-15
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2023-09-06
|
Related Activity
Type |
Referral |
Activity Nr |
1876289 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100147 C04 II B |
Issuance Date |
2022-09-15 |
Abatement Due Date |
2022-10-12 |
Current Penalty |
0.0 |
Initial Penalty |
14502.0 |
Contest Date |
2022-10-10 |
Final Order |
2023-06-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii)(B): The Energy Control Procedures in use did not include specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) On or about 3/17/2022 and at times prior to, 1701 Boone Blvd, Northport, AL, at the Yoder W60 Tube Mill, at the Ovaling Guide (OG) - Cut Off Operators aligning the pipe during set up prior to production were exposed to amputation hazards and no specific procedural steps were developed for the exclusive pendant control when placed in jog mode by the Cut Off Operator. |
|
|
345148217
|
0418300
|
2021-02-11
|
1701 BOONE BOULEVARD, NORTHPORT, AL, 35476
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-06-03
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2021-07-01
|
Related Activity
Type |
Referral |
Activity Nr |
1730388 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2021-06-10 |
Abatement Due Date |
2021-07-07 |
Current Penalty |
8874.45 |
Initial Penalty |
13653.0 |
Final Order |
2021-06-17 |
Nr Instances |
1 |
Nr Exposed |
15 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to pinch point hazards: (a) On or about 02/04/2021 - Shipping Department, employees were exposed to pinch point hazards when loading bundles of steel tubing onto a truck trailer. |
|
|
344398664
|
0418300
|
2019-10-24
|
1701 BOONE BLVD., NORTHPORT, AL, 35476
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-10-31
|
Case Closed |
2020-12-02
|
Related Activity
Type |
Referral |
Activity Nr |
1510264 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100028 B06 I |
Issuance Date |
2019-11-12 |
Current Penalty |
4250.4 |
Initial Penalty |
7084.0 |
Final Order |
2019-12-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(6)(i): The employer did not ensure each employee less than 4 feet (1.2 m) above dangerous equipment was protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system when the equipment was not covered or guarded to eliminate the hazard: (a) On or about 10/24/2019 - Tube Mill area, the platform above the 5K Tube Mill machine did not have a mid-rail installed on each side, exposing employees to fall hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2019-11-12 |
Abatement Due Date |
2019-12-30 |
Current Penalty |
7970.25 |
Initial Penalty |
10627.0 |
Final Order |
2019-12-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 10/18/2019 - Tube Mill area, Abbey Etna, 5K Tube Mill machine, the rotating feed roller shaft was not guarded, exposing employees to caught-in and crushed-by hazards. |
|
|
343630836
|
0418300
|
2018-11-29
|
3812 COMMERCE AVE., FAIRFIELD, AL, 35064
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-11-29
|
Case Closed |
2019-03-08
|
Related Activity
Type |
Referral |
Activity Nr |
1403003 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100028 B03 I |
Issuance Date |
2019-02-05 |
Abatement Due Date |
2019-03-04 |
Current Penalty |
13260.0 |
Initial Penalty |
13260.0 |
Final Order |
2019-02-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(3)(i): The employer did not ensure each employee was protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following: covers, guardrail systems, travel restraint systems, or personal fall arrest systems, as required by sub-items A through D of this section: a) On or about November 21, 2018 - Roof, employees were exposed to fall hazards of approximately 25 feet when they walked on the low slope roof to paint fans/vents, walked on the roof to check fans/vents, and walked on the roof to check the light near the wind sock without fall protection. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100030 C |
Issuance Date |
2019-02-05 |
Abatement Due Date |
2019-03-04 |
Current Penalty |
0.0 |
Initial Penalty |
8856.0 |
Final Order |
2019-02-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.30(a)(1): Before any employee was exposed to a fall hazard, the employer did not provide training for each employee who used personal fall protection systems or who was required to be trained as specified elsewhere in this subpart: or in the alternative 29 CFR 1910.30(c): The employer did not retrain an employee when the employer had reason to believe the employee did not have the understanding and skill required by paragraphs (a) and (b) of this section. Situations requiring retraining include, but are not limited to, the following: When changes in the workplace render previous training obsolete or inadequate; when changes in the types of fall protection systems or equipment to be used render previous training obsolete or inadequate; or when inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee no longer has the requisite understanding or skill necessary to use equipment or perform the job safely. a) On or about November 29, 2018 - Roof, employees were exposed to fall hazards when they had not been trained to know where to find an anchor for a harness/lanyard on the roof, had not been trained to stay 15 feet from all fall hazards if not using fall protection, had not been trained to use a guardrail system, safety net system, travel restraint system, or a personal fall arrest system (or a designated area when performing work that is both infrequent and temporary) between 6 and 15 feet from fall hazards, and had not been trained to use a guardrail system, safety net system, travel restraint system, or personal fall arrest system if less than 6 feet from a fall hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100037 B04 |
Issuance Date |
2019-02-05 |
Abatement Due Date |
2019-03-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-02-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: a) On or about November 29, 2018 - End of building where bay 1 and bay 2 are located, employees were exposed to fire hazards when there were no signs to indicate that the path to exit in the steel coil storage area was past racks into a chain link cage around materials on the floor to the side hinged door marked as an exit. |
|
|
341985414
|
0418300
|
2016-12-19
|
1701 BOONE BLVD., NORTHPORT, AL, 35476
|
|
Inspection Type |
Monitoring
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-12-19
|
Case Closed |
2016-12-20
|
Related Activity
Type |
Inspection |
Activity Nr |
1071775 |
Safety |
Yes |
|
|
341861532
|
0418300
|
2016-10-24
|
1701 BOONE BLVD., NORTHPORT, AL, 35476
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-10-24
|
Emphasis |
L: FORKLIFT, N: AMPUTATE
|
Case Closed |
2017-01-04
|
Related Activity
Type |
Complaint |
Activity Nr |
1146929 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2016-12-07 |
Abatement Due Date |
2017-01-04 |
Current Penalty |
3997.8 |
Initial Penalty |
6663.0 |
Final Order |
2016-12-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about 06/16/2016 - Warehouse Area, Hyster, Model S100XL, Serial #D004D08942X, procedures were not utilized by employee(s) replacing hydraulic cylinders in the forklift's carriage assembly. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100178 L04 III |
Issuance Date |
2016-12-07 |
Abatement Due Date |
2017-01-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-12-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: (a) On or about 10/24/2016 - Tube Mill Department, one forklift operator had not been evaluated since 10/17/2006. |
|
|
340821214
|
0418300
|
2015-07-29
|
1701 BOONE BOULEVARD, NORTHPORT, AL, 35476
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-09-21
|
Case Closed |
2016-01-19
|
Related Activity
Type |
Referral |
Activity Nr |
1004918 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2015-12-21 |
Abatement Due Date |
2016-01-19 |
Current Penalty |
4200.0 |
Initial Penalty |
7000.0 |
Final Order |
2016-01-04 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about 07/29/2015 - Main plant, 4X Tubemill cutoff, employees were cleaning the Turkshead rolls while the milling machine was in operation. |
|
|
340717750
|
0418300
|
2015-06-17
|
1701 BOONE BOULEVARD, NORTHPORT, AL, 35476
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-06-17
|
Case Closed |
2017-11-29
|
Related Activity
Type |
Referral |
Activity Nr |
991384 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1093769 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100132 A |
Issuance Date |
2015-09-23 |
Abatement Due Date |
2017-11-30 |
Current Penalty |
2475.0 |
Initial Penalty |
4950.0 |
Final Order |
2015-11-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) On or about 06/17/2015 - at the Shipping Area, protective equipment was not provided for employees exposed to varying fall hazard heights of about 5 to 8 feet when working on flatbed trailers for activities, such as but not limited to, unhooking bundles from the crane. Or, in the alternative: OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards: (a) On or about 06/17/2015 - at the Shipping Area, protective equipment was not provided for employees exposed to varying fall hazard heights of about 5 to 8 feet when working on flatbed trailers for activities such as but not limited to unhooking bundles from the crane. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2015-09-23 |
Abatement Due Date |
2016-05-30 |
Current Penalty |
5000.0 |
Initial Penalty |
7000.0 |
Final Order |
2015-11-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about 06/17/2015 - at the Tube Straightener, the ingoing nip points between the material and the rollers were not guarded. Or, in the alternative: OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to amputation hazards: (a) On or about 06/17/2015 - at the Tube Straightener, the ingoing nip points between the material and the rollers were not guarded. |
|
|
338917529
|
0418300
|
2013-02-25
|
1701 BOONE BOULEVARD, NORTHPORT, AL, 35476
|
|
Inspection Type |
Referral |
Scope |
Partial |
Safety/Health |
Health |
Close Conference |
2013-04-09 |
Emphasis |
L: HINOISE |
Case Closed |
2013-04-17 |
Related Activity
Type |
Referral |
Activity Nr |
805146 |
Health |
Yes |
|
|
338914070
|
0418300
|
2013-02-19
|
1701 BOONE BOULEVARD, NORTHPORT, AL, 35476
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2013-02-21 |
Emphasis |
L: FORKLIFT, L: HINOISE, P: AMPUTATE, N: AMPUTATE |
Case Closed |
2014-07-31 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100138 A |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
0.0 |
Initial Penalty |
6600.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion: a) On or about February 19, 2013 - Slitter department, employees take measurements while wearing loose gloves within 12 inches of rotating parts on the Slitter SL#11. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C05 I |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
1500.0 |
Initial Penalty |
7000.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: a) On or about February 25, 2013 - Tube mill department, Bay F, employees changing shims on a bearing block on the 12K stands, that weighed approximately 200 pounds did not have a wedge to ensure stability of the bearing block resulting in an amputation. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-16 |
Current Penalty |
1500.0 |
Initial Penalty |
7000.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) On or about February 19, 2013 - Tube mill department, Bay 1, and Compressor room, lockout/tagout procedures were not inspected for equipment such as the Slitter S/L-11, 3X Abbey Etna Tube Mill, 4X Abbey Etna Tube Mill, 5K Abbey Etna Tube Mill, and the HE&M Small Cutoff Saw. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
1500.0 |
Initial Penalty |
7000.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
5 |
Nr Exposed |
5 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) On or about February 19, 2013 - Tube mill department, Bay F, 12K Endwelder, an employee was not trained to recognize and minimize lockout/tagout hazards. b) On or about February 19, 2013 - Tube mill department, Bay F, 12K Tube mill, an employee was not trained to recognize and minimize lockout/tagout hazards. c) On or about February 19, 2013 - Tube mill department, Bay C, 5K Tube mill, an employee was not trained to recognize and minimize lockout/tagout hazards. d) On or about February 19, 2013 - Tube mill department, Bay C, 5K Cutoff, an employee was not trained to recognize and minimize lockout/tagout hazards. e) On or about February 19, 2013 - Slitter department, Slitter SL#11, an employee was not trained to recognize and minimize lockout/tagout hazards. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 III A |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(iii)(A): Retraining was not provided for authorized and affected employees when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the energy control procedures: a) On or about February 19, 2013 - Tube mill department and Warehouse, an employee was transferred from the Slitter SL#20 to Slitter SL#11 without retraining on lockout/tagout procedures. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100178 Q01 |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
0.0 |
Initial Penalty |
5500.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: a) On or about February 19, 2013 - Slitter department and Machine shop, Slitter SL#20, employees operate a 100 Hyster XL 2 FL#44 with damage to the tires and broken pendent control panel. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
1500.0 |
Initial Penalty |
7000.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about February 19, 2013 - Quality assurance department, a Marvel bandsaw, Series 8 Mark II S/N#827087 was being operated while the unguarded portion of the blade was exposed. b) On or about February 19, 2013 - Machine shop, a Bridgeport vertical milling machine S/N#2J144121 was being operated with unguarded rotating parts. c) On or about February 19, 2013 - Warehouse, Recut bay, a Little HEM Saw Model# V100LM-1, S/N#391393 was being operated while the unguarded portion of the blade was exposed. d) On or about February 19, 2013 - Tube mill, 5K-Cutoff, a Doall bandsaw was being operated with the unguarded portion of the blade exposed. |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
0.0 |
Initial Penalty |
7000.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposed an employee to injury, was not guarded: a) On or about February 19, 2013 - Slitter department, employees operating the Slitter/SL#11, S/N#4416 were not protected from rotating knives within 12 inches of the point of operation. b) On or about February 19, 2013 - Slitter department, employees operating Slitter/SL#11, S/N#4416 are required to clear scrap metal between the arbor and shear. |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19100215 A02 |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
0.0 |
Initial Penalty |
4400.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: a) On or about February 19, 2013 - Maintenance/Machine shop, a Jet Silicon Carbide abrasive wheel was missing the spindle end guards. |
|
Citation ID |
01009 |
Citaton Type |
Serious |
Standard Cited |
19100252 B02 III |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
1500.0 |
Initial Penalty |
4400.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not required to wear appropriate goggles, to protect them from the rays when noncombustible or flameproof screens or shields were not used: a) On or about March 25, 2013 - Slitter department, Slitter SL#11, employees were not protected from radiation burns from arc welding during machine set up. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100147 C04 I |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
17000.0 |
Initial Penalty |
38500.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about February 19, 2013 - Tube mill, Bay F, a specific procedure had not been established for employees that perform service, maintenance, or set up on equipment such as the 12K Tube Mill. b) On or about February 19, 2013 - Slitter department, a specific procedure had not been established for employees that perform service, maintenance, or set up on equipment such as the Slitter/SL#20. c) On or about February 19, 2013 - Tube mill, Bay D, a specific procedure had not been established for employees that perform service, maintenance, or set up on equipment such as the W60 Tube Mill. Hanna Steel Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.147(c)(4)(i), which was contained in OSHA inspection number 313010357, Citation number 02, Item number 002 and was affirmed as a final order on July 20, 2009, with respect to a workplace located at 3812 Commerce Avenue in Fairfield, AL 35064. |
|
Citation ID |
02002A |
Citaton Type |
Repeat |
Standard Cited |
19100215 A04 |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
15000.0 |
Initial Penalty |
22000.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
4 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch: a) On or about February 19, 2013 - Maintenance/Machine shop, the Jet abrasive wheel was not adjusted properly. b) On or about February 19, 2013 - Maintenance/Machine shop, the DeWalt DW758 abrasive wheel was not adjusted properly. c) On or about February 19, 2013 - Maintenance/Machine shop, the Gabriel 6-inch grinder, Model#09011602, was not adjusted properly. The Hanna Steel Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.215(a)(4), which was contained in OSHA inspection number 313010357, Citation number 01, Item number 005a and was affirmed as a final order on July 20, 2009, with respect to a workplace located at 3812 Commerce Avenue in Fairfield, AL 35064. |
|
Citation ID |
02002B |
Citaton Type |
Repeat |
Standard Cited |
19100215 B09 |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: a) On or about February 19, 2013 - Maintenance/Machine shop, the Jet abrasive wheel was not adjusted properly. b) On or about February 19, 2013 - Maintenance/Machine shop, the DeWalt DW758 abrasive wheel was not adjusted properly. The Hanna Steel Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.215(b)(9), which was contained in OSHA inspection number 313010357, Citation number 01, Item number 005b and was affirmed as a final order on July 20, 2009, with respect to a workplace located at 3812 Commerce Avenue in Fairfield, AL 35064. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19040032 B06 |
Issuance Date |
2013-07-29 |
Current Penalty |
500.0 |
Initial Penalty |
1100.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
162 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.32(b)(6): The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) for the previous year was not posted between February 1st and April 30th: a) On or about February 19, 2013 - Facility, the employer did not post the OSHA Form 300A or equivalent. |
|
Citation ID |
03002 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 I |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) On or about February 19, 2013 - Maintenance/Machine shop, employees wearing a 3M half-facepiece respirator were not provided a copy of Appendix D, "Information for Employees Using Respirators When Not Required Under the Standard". |
|
Citation ID |
03003 |
Citaton Type |
Other |
Standard Cited |
19100134 C02 II |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: a) On or about February 19, 2013 - Maintenance/Machine shop, employees voluntary utilized a 3M half-facepiece respirator while cutting G-10 MiCarter, Fiberglass, and epoxy materials. |
|
Citation ID |
03004A |
Citaton Type |
Other |
Standard Cited |
19101200 F05 I |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: a) On or about February 19, 2013 - Maintenance/Machine shop, Forklift repair area, plastic containers were not marked to identify the contents. |
|
Citation ID |
03004B |
Citaton Type |
Other |
Standard Cited |
19101200 F05 II |
Issuance Date |
2013-07-29 |
Abatement Due Date |
2013-08-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2013-08-20 |
Final Order |
2014-03-26 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: a) ) On or about February 19, 2013 - Maintenance/Machine shop, Forklift repair area, plastic containers were not marked. |
|
|
313010357
|
0418300
|
2009-03-25
|
3812 COMMERCE AVENUE, FAIRFIELD, AL, 35064
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2009-03-25 |
Emphasis |
N: SSTARG08 |
Case Closed |
2009-08-06 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-15 |
Current Penalty |
1688.0 |
Initial Penalty |
2250.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
Hazard |
STRUCK BY |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-15 |
Current Penalty |
1687.0 |
Initial Penalty |
2250.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100023 E01 |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100024 H |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-15 |
Current Penalty |
1350.0 |
Initial Penalty |
1800.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-16 |
Current Penalty |
1350.0 |
Initial Penalty |
1800.0 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-09 |
Current Penalty |
1350.0 |
Initial Penalty |
1800.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-15 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-16 |
Current Penalty |
1688.0 |
Initial Penalty |
2250.0 |
Nr Instances |
3 |
Nr Exposed |
4 |
Gravity |
03 |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19100219 E03 I |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-16 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01007A |
Citaton Type |
Serious |
Standard Cited |
19100303 F01 |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-16 |
Current Penalty |
1687.0 |
Initial Penalty |
2250.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01007B |
Citaton Type |
Serious |
Standard Cited |
19100305 J04 V |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-16 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 III |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-16 |
Current Penalty |
1688.0 |
Initial Penalty |
2250.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100132 D02 |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-07-16 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100147 C04 I |
Issuance Date |
2009-07-06 |
Abatement Due Date |
2009-08-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|
307478396
|
0418300
|
2004-04-06
|
3812 COMMERCE AVE, FAIRFIELD, AL, 35064
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2004-04-22 |
Emphasis |
N: AMPUTATE |
Case Closed |
2004-07-27 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100141 G02 |
Issuance Date |
2004-06-10 |
Abatement Due Date |
2004-06-29 |
Current Penalty |
1875.0 |
Initial Penalty |
1875.0 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19101048 H01 I |
Issuance Date |
2004-06-10 |
Abatement Due Date |
2004-06-29 |
Initial Penalty |
1875.0 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01003A |
Citaton Type |
Other |
Standard Cited |
19101048 M01 I |
Issuance Date |
2004-06-10 |
Abatement Due Date |
2004-08-31 |
Initial Penalty |
1875.0 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01003B |
Citaton Type |
Other |
Standard Cited |
19101048 M03 I |
Issuance Date |
2004-06-10 |
Abatement Due Date |
2004-08-31 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01004 |
Citaton Type |
Other |
Standard Cited |
19101048 M05 |
Issuance Date |
2004-06-10 |
Abatement Due Date |
2004-08-31 |
Initial Penalty |
1875.0 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01005 |
Citaton Type |
Other |
Standard Cited |
19101048 N01 |
Issuance Date |
2004-06-10 |
Abatement Due Date |
2004-08-31 |
Initial Penalty |
1125.0 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
01 |
|
Citation ID |
01006A |
Citaton Type |
Serious |
Standard Cited |
19101025 D01 II |
Issuance Date |
2004-06-10 |
Abatement Due Date |
2004-06-29 |
Current Penalty |
1875.0 |
Initial Penalty |
1875.0 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01006B |
Citaton Type |
Serious |
Standard Cited |
19101025 D02 |
Issuance Date |
2004-06-10 |
Abatement Due Date |
2004-06-29 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01006C |
Citaton Type |
Serious |
Standard Cited |
19101025 D07 |
Issuance Date |
2004-06-10 |
Abatement Due Date |
2004-06-29 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19101025 J01 I |
Issuance Date |
2004-06-10 |
Abatement Due Date |
2004-06-29 |
Current Penalty |
1875.0 |
Initial Penalty |
1875.0 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19101025 L01 I |
Issuance Date |
2004-06-10 |
Abatement Due Date |
2004-06-29 |
Current Penalty |
1875.0 |
Initial Penalty |
1875.0 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
03 |
|
|
100322049
|
0418300
|
1987-06-23
|
3001 HICKORY ST., GADSDEN, AL, 35902
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1987-06-23 |
Case Closed |
1987-08-12 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
1987-07-31 |
Abatement Due Date |
1987-08-12 |
Current Penalty |
400.0 |
Initial Penalty |
400.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
1987-07-31 |
Abatement Due Date |
1987-08-06 |
Current Penalty |
400.0 |
Initial Penalty |
400.0 |
Nr Instances |
3 |
Nr Exposed |
2 |
|
|
101571313
|
0418300
|
1986-07-09
|
3612 COMMERCE AVE., FAIRFIELD, AL, 35064
|
|
Inspection Type |
Referral |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
1986-07-10 |
Case Closed |
1986-08-28 |
Related Activity
Type |
Referral |
Activity Nr |
900691874 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100095 C01 |
Issuance Date |
1986-08-08 |
Abatement Due Date |
1986-08-22 |
Nr Instances |
7 |
Nr Exposed |
15 |
Related Event Code (REC) |
Referral |
|
|
101570752
|
0418300
|
1986-06-23
|
3812 COMMERCE AVENUE, FAIRFIELD, AL, 35064
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1986-06-24 |
Case Closed |
1986-09-16 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-24 |
Current Penalty |
320.0 |
Initial Penalty |
320.0 |
Nr Instances |
2 |
Nr Exposed |
4 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-12 |
Current Penalty |
240.0 |
Initial Penalty |
240.0 |
Nr Instances |
2 |
Nr Exposed |
3 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 I |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-15 |
Current Penalty |
320.0 |
Initial Penalty |
320.0 |
Nr Instances |
4 |
Nr Exposed |
5 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040002 A |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-15 |
Nr Instances |
1 |
Nr Exposed |
200 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100134 B01 |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-08-11 |
Nr Instances |
14 |
Nr Exposed |
14 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100213 H01 |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100213 H03 |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19100215 A04 |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-15 |
Nr Instances |
2 |
Nr Exposed |
8 |
|
Citation ID |
02006 |
Citaton Type |
Other |
Standard Cited |
19100215 B09 |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-15 |
Nr Instances |
1 |
Nr Exposed |
8 |
|
Citation ID |
02007 |
Citaton Type |
Other |
Standard Cited |
19100303 C |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
|
Citation ID |
02008 |
Citaton Type |
Other |
Standard Cited |
19100303 F |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-15 |
Nr Instances |
1 |
Nr Exposed |
6 |
|
Citation ID |
02009 |
Citaton Type |
Other |
Standard Cited |
19100304 A02 |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
|
Citation ID |
02010 |
Citaton Type |
Other |
Standard Cited |
19100304 F04 |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
|
Citation ID |
02011 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-15 |
Nr Instances |
1 |
Nr Exposed |
3 |
|
Citation ID |
02012 |
Citaton Type |
Other |
Standard Cited |
19100305 B02 |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-07-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
|
Citation ID |
02013 |
Citaton Type |
Other |
Standard Cited |
19101200 H |
Issuance Date |
1986-07-10 |
Abatement Due Date |
1986-08-11 |
Nr Instances |
1 |
Nr Exposed |
180 |
|
|