Search icon

Quin-Co., Inc.

Headquarter

Details

Name: Quin-Co., Inc.
Jurisdiction: Alabama
Legal type: Domestic Corporation
Status: Exists
Date of registration: 16 May 1977 (48 years ago)
Entity Number: 000-046-401
Register Number: 000046401
Place of Formation: Mobile County
Principal Address: EIGHT MILE, AL
Authorized Capital: $1,000
Paid Share Capital: $1,000

Links between entities

Type Company Name Company Number State
Headquarter of Quin-Co., Inc., MISSISSIPPI 673002 MISSISSIPPI

Incorporator

Name Role Address
MAPP, WILLARD Incorporator No data
BOSWELL, JOSEPH J Incorporator No data
CLEMENTS, ROBERT Incorporator 1517 13TH STREETTUSCALOOSA, AL 35401

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340792068 0418600 2015-07-22 3690 CARLYLE CLOSE E., MOBILE, AL, 36609
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2015-07-22
Emphasis P: FALL, L: FALL
Case Closed 2020-06-23

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2015-08-24
Abatement Due Date 2015-09-18
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-09-15
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a) At the worksite: On July 22, 2015 and at times prior to; employees were exposed to struck-by hazards from lifted construction materials in that the below-the-hook lifting device (spreader Bar) that was used to lift steel sections and metal roofing materials was not legibly marked.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2015-08-24
Abatement Due Date 2015-09-01
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2015-09-15
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems: (a) At the worksite at 3690 Carlyle Close, Mobile, AL: On July 22, 2015 and at times prior to; employees were exposed to falls of at least 18 feet, 3 inches while affixing metal sheets on a 3:12 pitch roof with open sides and edges in that employees were not protected from falls by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, fall restraint systems or fall protection plan.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260761 B
Issuance Date 2015-08-24
Abatement Due Date 2015-09-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.761(b): The employer shall train each employee and shall institute a training program and ensure employee participation in the program for each employee exposed to a fall hazards in accordance with the requirements of this section: (a) At the worksite: On July 22, 2015 and at times prior to; the employer exposed employees to falls of at least 18 feet while affixing metal decking on the roof of a metal structure in that all employees were not trained in the use of fall protection equipment or to identify hazards.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261412 F01
Issuance Date 2015-08-24
Abatement Due Date 2015-09-18
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-09-15
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1412(f)(1): The equipment was not inspected at least every 12 months by a qualified person in accordance with paragraph (d) of this section. (a) All locations: On July 22, 2015 and at times prior to; employees were exposed to struck by hazards from a truck crane that has not received an annual inspection by a qualified person.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261413 A02 I D
Issuance Date 2015-08-24
Abatement Due Date 2015-09-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-09-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1413(a)(2)(i)(D): A competent person must inspect end connections of the wire rope and ensure those connections are properly applied: (a) At the worksite: On July 22, 2015 and at times prior to; employees were exposed to struck-by a crane load in that a competent person did not properly inspect the terminal end of the truck crane's wire rope in that the dead end of the wire rope passing through the Crosby wedge socket, was secured to the live end of the wire rope with a saddle clamp, creating a pinch of the live rope and an impending failure.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261417 E01 I
Issuance Date 2015-08-24
Current Penalty 1020.0
Initial Penalty 1020.0
Final Order 2015-09-15
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1417(e)(1)(i): The operator must not leave a load suspended while occupied with other duties: (a) On the Northwest corner of the metal building being erected: On July 22, 2015 and at times prior to; employees were exposed to struck by hazards from a suspended load of insulation weighing approximately 200 pounds in that the operator did not remain adjacent to the suspended load and the operator was engaged in other activities.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261425 C02
Issuance Date 2015-08-24
Abatement Due Date 2015-09-01
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-09-15
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1425(c)(2): The employer did not make sure that hooks with self-closing latches were used while employees were hooking, unhooking, or guiding the load. (a) At the worksite: On July 22, 2015 and at times prior to; the employer exposed employees to struck-by hazards in that the truck crane hook was not provided with a self closing latch.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4022977710 2020-05-01 0459 PPP 3345 ANTON ST, MOBILE, AL, 36612
Loan Status Date 2021-12-16
Loan Status Charged Off
Loan Maturity in Months 4
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 59852
Loan Approval Amount (current) 59852
Undisbursed Amount 0
Franchise Name -
Lender Location ID 12096
Servicing Lender Name Wells Fargo Bank, National Association
Servicing Lender Address 101 N Philips Ave, SIOUX FALLS, SD, 57104-6738
Rural or Urban Indicator U
Hubzone Y
LMI N
Business Age Description Existing or more than 2 years old
Project Address MOBILE, MOBILE, AL, 36612-1100
Project Congressional District AL-01
Number of Employees 7
NAICS code 236210
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 12096
Originating Lender Name Wells Fargo Bank, National Association
Originating Lender Address SIOUX FALLS, SD
Gender Unanswered
Veteran Unanswered
Forgiveness Amount -
Forgiveness Paid Date -

Date of last update: 30 Jul 2024

Sources: Alabama Secretary of State