345640551
|
0418300
|
2021-11-16
|
3310 HI-LO CIRCLE, HUNTSVILLE, AL, 35811
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-01-05
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2022-02-18
|
Related Activity
Type |
Referral |
Activity Nr |
1831554 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2022-01-24 |
Abatement Due Date |
2022-02-17 |
Current Penalty |
5288.4 |
Initial Penalty |
8136.0 |
Final Order |
2022-02-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about 10/18/2021 - Remanufacturing Area, Weinig Hydromat Moulder #2, procedures were not utilized by employees removing wood pieces stuck inside the rotating bottom head blade of the machine exposing employees to amputation hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2022-01-24 |
Current Penalty |
3525.6 |
Initial Penalty |
5424.0 |
Final Order |
2022-02-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed: (a) On or about 11/16/2021 - Remanufacturing Area, Chain Deck Feeding Machine, the sprockets and chain were not guarded exposing employees to caught-in and amputation hazards. |
|
|
345328488
|
0418300
|
2021-05-19
|
3310 HI LO CIRCLE, HUNTSVILLE, AL, 35811
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-10-28
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2021-12-15
|
Related Activity
Type |
Referral |
Activity Nr |
1767590 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1532879 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1533189 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100138 B |
Issuance Date |
2021-11-09 |
Abatement Due Date |
2021-12-07 |
Current Penalty |
0.0 |
Initial Penalty |
7660.0 |
Final Order |
2021-12-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.138(b): The employer did not base selection of appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the tasks to be performed, conditions present, duration of use, and the hazards and potential hazards identified: (a) On or about May 12, 2021 - Drilling station in plant, employees were exposed to amputation hazards when loose fitting gloves were used while inserting boards into the drilling station machine. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2021-11-09 |
Abatement Due Date |
2021-12-07 |
Current Penalty |
3829.5 |
Initial Penalty |
5106.0 |
Final Order |
2021-12-06 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about May 19, 2021 - Drilling station in plant, employees were exposed to struck-by hazards when there was no machine specific lockout/tagout procedure for the drilling station that had more than one energy source. (b) On or about May 19, 2021 - Drilling station in plant, employees were exposed to struck-by hazards when lockout/tagout was not performed by employees who cleaned around/back of the drilling station. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I |
Issuance Date |
2021-11-09 |
Abatement Due Date |
2021-12-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-12-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: (a) On or about May 19, 2021- Drilling station in plant, employees were exposed to struck-by hazards when temporary employees had not been trained to perform lockout/tagout while cleaning around the drilling station and had not been instructed in the purpose/use of lockout/tagout when other employees performed lockout/tagout. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A03 II |
Issuance Date |
2021-11-09 |
Abatement Due Date |
2021-12-07 |
Current Penalty |
3829.5 |
Initial Penalty |
5106.0 |
Final Order |
2021-12-06 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) On or about May 19, 2021 - Drilling station in plant, employees were exposed to struck-by hazards when the back of the machine was not guarded and drill bits/hold down bolts could be inadvertently accessed while the machine was running. (b) On or about May 12, 2021 - Drilling station in plant, employees were exposed to struck-by hazards when it was necessary to place boards onto the bed of the machine while the drill bits were turning. (c) On or about May 12, 2021 - Drilling station in plant, employees were exposed to struck-by hazards when it was necessary to hold boards onto the bed of the machine while causing the bed to rise toward the turning drill bits and the spring loaded hold down bolts. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2021-11-09 |
Abatement Due Date |
2021-12-07 |
Current Penalty |
3829.5 |
Initial Penalty |
5106.0 |
Final Order |
2021-12-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) On or about May 19, 2021 - Drilling station in plant, employees were exposed to struck-by hazards when the pulleys for the four sets of drill bits were not guarded on the back side of the station and were accessible from the front of the station. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100219 E03 I |
Issuance Date |
2021-11-09 |
Abatement Due Date |
2021-12-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-12-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): (a) On or about May 19, 2021 - Drilling station in plant, employees were exposed to struck-by hazards when the belts for the four sets of drill bits were not guarded on the back side of the station and were accessible from the front of the station. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2021-11-09 |
Abatement Due Date |
2021-12-07 |
Current Penalty |
3829.5 |
Initial Penalty |
5106.0 |
Final Order |
2021-12-06 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: (a) On or about May 19, 2021 - Plant, employees were exposed to struck-by hazards when the chain/sprocket conveyors next to the aisle toward the drilling stations and near the women's restroom were not enclosed. |
|
Citation ID |
01006 |
Citaton Type |
Other |
Standard Cited |
19100265 C20 II |
Issuance Date |
2021-11-09 |
Abatement Due Date |
2021-12-07 |
Current Penalty |
3829.0 |
Initial Penalty |
3829.0 |
Final Order |
2021-12-06 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.265(c)(20)(ii): Machine(s) that created dust, shavings, chips, or slivers during a period of time equal to or greater than one-fourth of the working day were not equipped with collecting system(s): (a)On or about May 19, 2021 - drilling station in plant, employees were exposed to wood dust when the drilling station did not have a dust collecting system. |
|
|
345331896
|
0418300
|
2021-05-19
|
3310 NORTH HI-LO CIRCLE, HUNTSVILLE, AL, 35811
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-10-28
|
Case Closed |
2021-12-07
|
Related Activity
Type |
Inspection |
Activity Nr |
1532848 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1532879 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1488582 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19101200 H01 |
Issuance Date |
2021-11-08 |
Abatement Due Date |
2021-12-06 |
Current Penalty |
360.6 |
Initial Penalty |
601.0 |
Final Order |
2021-12-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On or about May 19, 2021 - 3310 North Hi-Lo Circle, Huntsville, AL, temporary employees did not receive hazard communication training when starting work at the site. Employees packed, counted product, and operated machines that performed work such as, but not limited to, drilling wood. L & L Lumber Co., Inc. was previously cited for a violation of this Occupational Safety and Health Standard, 29 CFR 1910.1200(h)(1), which was contained in OSHA Inspection number 1488582 , citation number 2, item number 3 and was affirmed as a final order on 02/05/2021, with respect to a workplace located at 3310 North Hi-Lo Circle, Huntsville, AL 35811. |
|
|
344885827
|
0418300
|
2020-08-13
|
3310 NORTH HI LO CIRCLE, HUNTSVILLE, AL, 35811
|
|
Inspection Type |
Fat/Cat
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-01-14
|
Emphasis |
L: LANDSCPE
|
Case Closed |
2021-02-10
|
Related Activity
Type |
Referral |
Activity Nr |
1640363 |
Safety |
Yes |
|
Type |
Accident |
Activity Nr |
1649948 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2021-01-14 |
Abatement Due Date |
2021-02-10 |
Current Penalty |
9745.8 |
Initial Penalty |
13494.0 |
Final Order |
2021-02-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm exposing employees to struck-by hazards: (a) On or about August 05, 2020 - Wooded area near fence, the employer allowed employees to cut down trees without requiring them to follow safe work practices for felling trees, exposing them to struck-by hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100132 A |
Issuance Date |
2021-01-14 |
Abatement Due Date |
2021-02-10 |
Current Penalty |
2968.9 |
Initial Penalty |
5398.0 |
Final Order |
2021-02-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(a): Protective equipment was not provided or used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) On or about August 05, 2020 - Wooded area near fence, an employee cutting down trees was exposed to struck-by and laceration hazards when the employee was not wearing chaps or cut-resistant leg protection. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100132 D01 |
Issuance Date |
2021-01-14 |
Abatement Due Date |
2021-02-10 |
Current Penalty |
2968.9 |
Initial Penalty |
5398.0 |
Final Order |
2021-02-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: (a) On or about August 13, 2020 - Wooded area near fence, an employee was exposed to struck-by hazards when the employer had not determined the personal protective equipment necessary when cutting trees with a chain saw such as, but not limited to, protective shoes, head protection, and cut-resistant leg protection. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100135 A01 |
Issuance Date |
2021-01-14 |
Abatement Due Date |
2021-02-10 |
Current Penalty |
5165.3 |
Initial Penalty |
9446.0 |
Final Order |
2021-02-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects: (a) On or about August 05, 2020 - Wooded area near fence, an employee was exposed to struck-by hazards when the employee did not wear a hardhat while cutting down trees with a machete and chain saw. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100136 A |
Issuance Date |
2021-01-14 |
Abatement Due Date |
2021-02-10 |
Current Penalty |
2968.9 |
Initial Penalty |
5398.0 |
Final Order |
2021-02-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.136(a): The employer did not ensure that each affected employee uses protective footwear when working in areas where there is a danger of foot injuries due to falling or rolling objects, or objects piercing the sole, or when the use of protective footwear will protect the affected employee from an electrical hazard, such as a static-discharge or electric-shock hazard, that remains after the employer takes other necessary protective measures: (a) On or about August 05, 2020 - Wooded area near fence, employees were exposed to struck-by hazards when the employee cutting down trees was not required to use safety shoes when cutting down trees or when cutting grass with a push mower. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2021-01-14 |
Current Penalty |
3710.8 |
Initial Penalty |
6747.0 |
Final Order |
2021-02-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye: (a) On or about August 07, 2020 - 3310 N Hi-Lo Circle, Huntsville, AL, the employer did not report the hospitalization of an employee who was injured on August 05, 2020 at 1:00 P.M. until August 07, 2020. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 G01 |
Issuance Date |
2021-01-14 |
Abatement Due Date |
2021-02-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-02-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: (a) On or about August 13, 2020 - 3310 N Hi Lo Circle, Huntsville, AL, employees using chemicals such as, but not limited to, disinfectant cleaners, lumber treated with pesticides, gas, diesel, propane, and oil did not have access to safety data sheets when the employer could not locate the binders and the employees did not know where to look for the binders. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2021-01-14 |
Abatement Due Date |
2021-02-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-02-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On or about August 13, 2020 - 3310 N Hi Lo Circle, Huntsville, AL, training for employees using chemicals such as, but not limited to, disinfectant cleaners, lumber treated with pesticides, gas, diesel, propane, and oil did not include where to find safety data sheets or what information was available on a safety data sheet. |
|
|
344597885
|
0418300
|
2020-01-21
|
17106 N HIGHWAY 35, SCOTTSBORO, AL, 35768
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2020-01-21
|
Case Closed |
2020-06-02
|
Related Activity
Type |
Complaint |
Activity Nr |
1534336 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100022 A01 |
Issuance Date |
2020-05-06 |
Abatement Due Date |
2020-06-02 |
Current Penalty |
2428.8 |
Initial Penalty |
4048.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition.: (a) On or about January 21, 2020 - Pallet area, employees were exposed to trip hazards when air hoses, band straps, and wood debris were lying across the walking areas in and around the pallet nailing area. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100036 B01 |
Issuance Date |
2020-05-06 |
Abatement Due Date |
2020-06-02 |
Current Penalty |
2428.8 |
Initial Penalty |
4048.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(b)(1): At least two exits routes were not available to permit prompt evacuation of employees during an emergency: (a) On or about January 21, 2020 - Office and production areas, employees were exposed to fire hazards when there were no exits visible in the office building or in the production areas: |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2020-05-06 |
Abatement Due Date |
2020-06-02 |
Current Penalty |
3238.8 |
Initial Penalty |
5398.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: (a) On or about January 21, 2020 - Maintenance area, employees were exposed to eye injuries when there was no eye wash in the area where maintenance put water into the forklift batteries. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2020-05-06 |
Current Penalty |
2428.8 |
Initial Penalty |
4048.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): (a) On or about January 21, 2020 - Production area, employees were exposed to struck-by hazards when employees using forklifts had not been trained/evaluated/certified to drive the forklifts. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100178 Q07 |
Issuance Date |
2020-05-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: (a) On or about January 21, 2020 - Production area, employees were exposed to struck-by hazards when forklifts used on a daily basis were not inspected prior to daily use. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 I |
Issuance Date |
2020-05-06 |
Abatement Due Date |
2020-06-02 |
Current Penalty |
2428.8 |
Initial Penalty |
4048.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) On or about January 21, 2020 - Break area, employees were exposed to electric shock hazards when receptacle outlet boxes did not have covers. A heater was plugged into one of the receptacles. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100157 C01 |
Issuance Date |
2020-05-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: (a) On or about January 21, 2020 - Facility, employees were exposed to fire hazards when fire extinguisher locations were not marked and fire extinguishers were located on the floor. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 II |
Issuance Date |
2020-05-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) On or about January 21, 2020 - Production area, employees were exposed to struck-by hazards when materials were stored in front of electrical panels. |
|
Citation ID |
02003A |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2020-05-06 |
Abatement Due Date |
2020-06-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) On or about January 21, 2020 - Production area, a written hazard communication program had not been developed and implemented for employees working with hazardous chemicals, including, but not limited to, propane and battery acid. |
|
Citation ID |
02003B |
Citaton Type |
Other |
Standard Cited |
19101200 G01 |
Issuance Date |
2020-05-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they used: (a) On or about January 21, 2020 - Production area, safety data sheets were not maintained for hazardous chemicals including, but not limited to, propane and battery acid. |
|
Citation ID |
02003C |
Citaton Type |
Other |
Standard Cited |
19101200 H01 |
Issuance Date |
2020-05-06 |
Abatement Due Date |
2020-06-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On or about January 21, 2020 - Production area, hazard communication training employees had not been provided for employees working with hazardous chemicals including, but not limited to, propane and battery acid. |
|
|
339479073
|
0418300
|
2013-11-07
|
109A WHOLESALE AVENUE N. E., HUNTSVILLE, AL, 35811
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-11-07
|
Emphasis |
N: AMPUTATE, L: FALL
|
Case Closed |
2015-12-29
|
Related Activity
Type |
Referral |
Activity Nr |
859591 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100024 H |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-28 |
Current Penalty |
1190.0 |
Initial Penalty |
2380.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: (a) On or about 11/07/13 - Holtec Saw Area, handrails were not provided at the stairway leading to the Holtec saw platform. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-09-15 |
Current Penalty |
3500.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-05-02 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: (a) On or about 11/07/13 - Tennor saw, a guard was not provided for the 14 inch rotating saw blade. (b) On or about 11/07/13 - Stringer saw, a guard was not provided for the 32 inch rotating saw blade. (c) On or about 11/07/13 - Holtec saw, a guard was not provided at the side of the saw blade. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100213 C01 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-28 |
Current Penalty |
1800.0 |
Initial Penalty |
2975.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: (a) On or about 11/07/13 - Ripline Resaw, right end of the line, the portion of the circular saw blade above the table was not provided with an adjusting guard over the blade. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-17 |
Current Penalty |
1190.0 |
Initial Penalty |
2380.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: (a) On or about 11/07/13 - Maintenance Shop, the work rest on the Milwaukee 8-inch bench grinder was adjusted at 1/2 inch away from the abrasive wheel. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: (a) On or about 11/07/13 - Maintenance Shop, the tongue guard for the 8-inch Milwaukee bench grinder was adjusted at one inch. |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-09-15 |
Current Penalty |
1450.0 |
Initial Penalty |
2380.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) On or about 11/7/13 - Motor for the dust system, a guard was not provided for the pulley assembly. (b) On or about 11/07/13 - Planer Outfeed, a guard was not provided for the pulley assembly at the chain conveyor. (c) On or about 11/07/13 - Stringer Saw, a guard was not provided for the pulley assembly. |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19100219 E01 I |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-09-15 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: (a) On or about 11/7/13 - Notcher motor for the dust system, a guard was not provided for the 2" rotating belt for the belt and pulley assembly. (b) On or about 11/07/13 - Planer Outfeed, a guard was not provided for the 2" rotating belt for the belt and pulley assembly. (c) On or about 11/07/13 - Stringer Saw, a guard was not provided for the 1" belt and pulley assembly. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100219 F03 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-28 |
Current Penalty |
3500.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-05-02 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: (a) On or about 11/07/13 - Planer Outfeed, the chain conveyor system that moves lumber from the planer for stacking had a chain and sprocket assembly that was not provided with a guard. (b) On or about 11/07/13 - Roller System, the chain and sprocket assembly was not provided with a guard. (c) On or about 11/07/13 - Morgan Saw, the chain and sprocket assembly at the conveyor was not provided with a guard. (d) On or about 11/07/13 - Tennor Saw, the chain and sprocket assembly at the conveyor was not provided with a guard. |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 III |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-17 |
Current Penalty |
1500.0 |
Initial Penalty |
2975.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: (a) On or about 11/7/13 - Maintenance Shop, oxygen and acetylene cylinder(s) were stored together. |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19100265 C04 IV |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-28 |
Current Penalty |
500.0 |
Initial Penalty |
2380.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.265(c)(4)(iv): Elevated platform(s), 4 feet or more from the floor level, were not provided with a standard railing: (a) On or about 11/07/13 - Sticking Machine Platform, employees were not protected from falling from the platform while performing sticking operation. |
|
Citation ID |
01009 |
Citaton Type |
Serious |
Standard Cited |
19100265 C27 III |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-21 |
Current Penalty |
2000.0 |
Initial Penalty |
2975.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.265(c)(27)(iii): Unstable pile(s) of lumber were not immediately made safe, or the area into which the unstable piles might fall was not fenced or barricaded and employees prohibited from entering it: (a) On or about 11/07/13 - Lumber yard, stacks of lumber were unstable, exposing employees to the hazard of being struck by falling lumber. |
|
Citation ID |
01010 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-28 |
Current Penalty |
3000.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-05-02 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) On or about 11/07/13 - Newman KM-16 Resaw, two knockouts were missing from the 480 volt electrical disconnect box. (b) On or about 11/07/13 - Newman KM-16 Resaw, one of the knockouts was missing from the 240 volt electrical disconnect box. |
|
Citation ID |
01011 |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-28 |
Current Penalty |
3000.0 |
Initial Penalty |
4900.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): (a) On or about 11/07/13 - Morgan Resaw, the 480 volt conductor for the blower was run through the wall. |
|
Citation ID |
01012 |
Citaton Type |
Serious |
Standard Cited |
19100305 J04 V |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-28 |
Current Penalty |
1475.0 |
Initial Penalty |
2380.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(j)(4)(v): The disconnecting means were not readily accessible: (a) On or about 11/07/13 - Planer Heads, the two 480 volt electrical disconnects were not readily accessible in that they were blocked by several items such as, but not limited to old equipment and cords. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100147 C04 II B |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-05-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) On or about 11/07/13 - L & L Lumber Co., Inc., specific procedural steps were not developed and implemented for the control of hazardous energy for machinery with more than one source of energy. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100147 C06 II |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-05-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) On or about 11/26/13 - L & L Lumber Co., Inc., the employer did not certify that an annual inspection of the energy control procedures had been performed. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100157 C04 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
2 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition: (a) On or about 11/07/13 - Tilt Hoist Unscrambler, the fire extiguisher at the Northwest end of the platform had not been recharged. (b) On or about 11/07/13 - Tilt Hoist Unscrambler, the fire extinguisher at the Northeast end of the platform had not been recharged. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19100157 E01 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-05-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(e)(1): The employer was not responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace: (a) On or about 11/07/13 - At tilt hoist unscrambler, two of three fire extinguishers had not been inspected. (b) On or about 11/07/13 - At the Stringer Saw, the fire extinguisher had not been inspected. |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19101200 F05 I |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
5 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein: (a) On or about 11/07/13 - Maintenance Shop/Grinding Room, a 5-gallon container labeled oil dry had the chemical citri solve inside. (b) On or about 11/07/13 - Maintenance Shop/Grinding Room, four red 5-gallon containers labeled gasoline had water inside. (c) On or about 11/07/13 - Maintenance Shop/Grinding Room, a blue 5-gallon container was not labeled to identify the contents within. (d) On or about 11/07/13 - Maintenance Shop/Grinding Room, two 5-gallon containers labeled hydraulic oil had the chemical citri solve inside. (e) On or about 11/07/13 - Maintenance Shop/Grinding Room, a 1-gallon container was not labeled to identify the contents within. (f) On or about 11/07/13 - Maintenance Shop/Grinding Room, one 16oz bottle of chemical was not labeled to identify the contents within. |
|
Citation ID |
02006 |
Citaton Type |
Other |
Standard Cited |
19101200 F05 II |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5)(ii): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the appropriate hazard warnings: (a) On or about 11/07/13 - Shop Area, a three gallon container of diesel fuel was not labeled with the appropriate warnings. |
|
|
339434557
|
0418300
|
2013-10-21
|
3310 NORTH HI LO CIRCLE, HUNTSVILLE, AL, 35811
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2013-10-30
|
Emphasis |
L: HINOISE
|
Case Closed |
2015-12-29
|
Related Activity
Type |
Complaint |
Activity Nr |
855703 |
Safety |
Yes |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100095 C01 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-05-27 |
Current Penalty |
2500.0 |
Initial Penalty |
3570.0 |
Final Order |
2014-05-02 |
Nr Instances |
6 |
Nr Exposed |
25 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: (a) On or about 10/30/13 - The Planer Feed Operator was exposed to continuous noise at 305.0% of the allowable 8-hour time-weighted average sound level of 85 dBA or an equivalent level of 98.0 dBA. The sampling was performed for 446 minutes during one shift. Zero exposure was assumed for the unsampled time of 34 minutes. (b) On or about 10/30/13 - The Moulder Feed Operator was exposed to continuous noise at 85.9% of the allowable 8-hour time-weighted average sound level of 85 dBA or an equivalent level of 88.9 dBA. The sampling was performed for 444 minutes during one shift. Zero exposure was assumed for the unsampled time of 36 minutes. (c) On or about 10/30/13 - The Multi-cut Trim Saw Operator was exposed to continuous noise at 93.4% of the allowable 8-hour time-weighted average sound level of 85 dBA or an equivalent level of 89.5 dBA. The sampling was performed for 448 minutes during one shift. Zero exposure was assumed for the unsampled time of 32 minutes. (d) On or about 10/30/13 - The Rip Line operator was exposed to continuous noise at 78.3% of the allowable 8-hour time-weighted average sound level of 85 dBA or an equivalent level of 88.2 dBA. The sampling was performed for 446 minutes during one shift. Zero exposure was assumed for the unsampled time of 34 minutes. (e) On or about 10/30/13 - The Stringer Machine(old) Operator was exposed to continuous noise at 129.9% of the allowable 8-hour time-weighted average sound level of 85 dBA or an equivalent level of 91.9 dBA. The sampling was performed for 431 minutes during one shift. Zero exposure was assumed for the unsampled time of 49 minutes. (f) On or about 10/30/13 - The Shaper Feed Operator was exposed to continuous noise at 117.7% of the allowable 8-hour time-weighted average sound level of 85 dBA or an equivalent level of 91.2 dBA. The sampling was performed for 450 minutes during one shift. Zero exposure was assumed for the unsampled time of 30 minutes. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100178 P01 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-05-27 |
Current Penalty |
1250.0 |
Initial Penalty |
2380.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): (a) On or about 10/20/13 - Outside wood storage shed, the back-up alarm and brake lights were not operable on the forklift, Cat Model P6500. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100265 C20 II |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-09-15 |
Current Penalty |
900.0 |
Initial Penalty |
1785.0 |
Final Order |
2014-05-02 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.265(c)(20)(ii): Machine(s) that created dust, shavings, chips, or slivers during a period of time equal to or greater than one-fourth of the working day were not equipped with collecting system(s): (a) On or about 10/13/13 - Remanufacturing plant, the old stringer machine was not connected to a dust collection system. (b) On or about 10/13/13 - Remanufacturing plant, the new stringer machine was not connected to a dust collection system. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100037 B02 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-05-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
40 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": (a) On or about 10/21/13 - Remanufacturing plant, exits were not identified. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100132 D02 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-04-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
40 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: (a) On or about 10/21/13 - at Facility, a certification of personal protective equipment workplace assessment had not been completed for the site. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100146 C01 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-05-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: (a) On or about 10/21/13 - Re-Manufacturing facility, confined spaces such as the wood grinder were not evaluated and identified by signage. |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-05-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
40 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) On or about 10/21/13 - at Facility, a written hazard communicaton program had not been developed for employees exposed to wood dust, residual amounts of chemicals in treated lumber, fuels and lubricants. |
|
Citation ID |
02005 |
Citaton Type |
Other |
Standard Cited |
19101200 H |
Issuance Date |
2014-04-09 |
Abatement Due Date |
2014-05-05 |
Current Penalty |
350.0 |
Initial Penalty |
595.0 |
Final Order |
2014-05-02 |
Nr Instances |
1 |
Nr Exposed |
20 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h): Employees were not provided effective information and training as specified in 29 CFR 1910.1200(h)(1) and -2 on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced: (a) On or about 10/21/13 - at Facility, employees had not been provided specific information on their potential exposure to wood dust, diesel fuel, and lubricants in their working environment. Training should include the location and access to material safety data sheets. |
|
|