Name: | Coastal Utilities, Inc. |
Jurisdiction: | Alabama |
Legal type: | Domestic Corporation |
Status: | Exists |
Date of registration: | 09 Dec 2011 (13 years ago) |
Entity Number: | 000-033-720 |
Register Number: | 000033720 |
ZIP code: | 36542 |
County: | Baldwin |
Place of Formation: | Baldwin County |
Registered Office Street Address: | 20050 OAK ROAD E #807GULF SHORES, AL 36542 |
Authorized Capital: | 100,000 @ NPV |
Activities
INSTALL UNDERGROUND UTILITIES/COMMUNICATION SERVICES
Name | Role | Address |
---|---|---|
TAYLOR, JOHN F | Agent | 20050 OAK ROAD E #807GULF SHORES, AL 36542 |
Name | Role | Address |
---|---|---|
ALBRITTON, KEVIN JAMES | Director | 27467 US HWY 98ELBERTA, AL 36530 |
TAYLOR, JOHN FRANK | Director | 20050 OAK ROAD E #807GULF SHORES, AL 36542 |
Name | Role | Address |
---|---|---|
TAYLOR, JOHN F | Incorporator | 20050 OAK ROAD E #807GULF SHORES, AL 36542 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339930968 | 0418600 | 2014-09-02 | PLANTATION ESTATES, DAPHNE, AL, 36526 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 993003 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260651 C02 |
Issuance Date | 2014-09-30 |
Abatement Due Date | 2014-10-08 |
Current Penalty | 880.0 |
Initial Penalty | 1200.0 |
Final Order | 2014-10-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) On or about August 22, 2014; egress from a trench: The employer failed to ensure employees conducting repair work to an AT&T communication cable had proper points of egress no more than 25 feet from their work location. Employees working at the West end were about 25 feet or more away from a stepped down ramp at the East end resulting in them climbed out of the almost vertical West end with no ladder, slope, ramp, or stairway. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260651 J02 |
Issuance Date | 2014-09-30 |
Abatement Due Date | 2014-10-08 |
Current Penalty | 880.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-10-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations, or by a combination of both if necessary: a) On or about August 22, 2014; equipment over excavation: The employer failed to ensure the excavator was kept at least 2 feet from the edge/end of the excavation by having the excavator straddle over the excavation presenting a hazard of falling/rolling in with employees working in it. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2014-09-30 |
Abatement Due Date | 2014-10-08 |
Current Penalty | 880.0 |
Initial Penalty | 1600.0 |
Final Order | 2014-10-15 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): a) On or about August 22, 2014; protective system: The employer failed to ensure some type of protective system such as a trench box was used to protect employees from the hazards associated with cave-ins while employees were working on repairing an AT&T cable in an excavation about 6 feet deep. |
Date of last update: 30 Jul 2024
Sources: Alabama Secretary of State