Search icon

Coastal Utilities, Inc.

Details

Name: Coastal Utilities, Inc.
Jurisdiction: Alabama
Legal type: Domestic Corporation
Status: Exists
Date of registration: 09 Dec 2011 (13 years ago)
Entity Number: 000-033-720
Register Number: 000033720
ZIP code: 36542
County: Baldwin
Place of Formation: Baldwin County
Registered Office Street Address: 20050 OAK ROAD E #807GULF SHORES, AL 36542
Authorized Capital: 100,000 @ NPV

Activities INSTALL UNDERGROUND UTILITIES/COMMUNICATION SERVICES

Agent

Name Role Address
TAYLOR, JOHN F Agent 20050 OAK ROAD E #807GULF SHORES, AL 36542

Director

Name Role Address
ALBRITTON, KEVIN JAMES Director 27467 US HWY 98ELBERTA, AL 36530
TAYLOR, JOHN FRANK Director 20050 OAK ROAD E #807GULF SHORES, AL 36542

Incorporator

Name Role Address
TAYLOR, JOHN F Incorporator 20050 OAK ROAD E #807GULF SHORES, AL 36542

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339930968 0418600 2014-09-02 PLANTATION ESTATES, DAPHNE, AL, 36526
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2014-09-02
Emphasis N: TRENCH, P: TRENCH
Case Closed 2014-10-15

Related Activity

Type Inspection
Activity Nr 993003
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260651 C02
Issuance Date 2014-09-30
Abatement Due Date 2014-10-08
Current Penalty 880.0
Initial Penalty 1200.0
Final Order 2014-10-15
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) On or about August 22, 2014; egress from a trench: The employer failed to ensure employees conducting repair work to an AT&T communication cable had proper points of egress no more than 25 feet from their work location. Employees working at the West end were about 25 feet or more away from a stepped down ramp at the East end resulting in them climbed out of the almost vertical West end with no ladder, slope, ramp, or stairway.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260651 J02
Issuance Date 2014-09-30
Abatement Due Date 2014-10-08
Current Penalty 880.0
Initial Penalty 1600.0
Final Order 2014-10-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(j)(2): Employees were not protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations, or by a combination of both if necessary: a) On or about August 22, 2014; equipment over excavation: The employer failed to ensure the excavator was kept at least 2 feet from the edge/end of the excavation by having the excavator straddle over the excavation presenting a hazard of falling/rolling in with employees working in it.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260652 A01
Issuance Date 2014-09-30
Abatement Due Date 2014-10-08
Current Penalty 880.0
Initial Penalty 1600.0
Final Order 2014-10-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): a) On or about August 22, 2014; protective system: The employer failed to ensure some type of protective system such as a trench box was used to protect employees from the hazards associated with cave-ins while employees were working on repairing an AT&T cable in an excavation about 6 feet deep.

Date of last update: 30 Jul 2024

Sources: Alabama Secretary of State