Name: | Zekelman Industries, Inc. |
Jurisdiction: | Alabama |
Legal type: | Foreign Corporation |
Status: | Withdrawn |
Date of registration: | 13 Feb 2006 (19 years ago) |
Entity Number: | 000-027-992 |
Register Number: | 000027992 |
Historical Names: |
JMC Steel Group, Inc.
|
ZIP code: | 36104 |
County: | Montgomery |
Place of Formation: | Delaware |
Principal Address: | 227 W. MONROE STREET, 26TH FLOORCHICAGO, IL 60606 |
Registered Office Street Address: | 2 NORTH JACKSON STREET, SUITE 605MONTGOMERY, AL 36104 |
Name | Role | Address |
---|---|---|
CT CORPORATION SYSTEM | Agent | 6190 POWERS FERRY RD STE 600ATLANTA, GA 30339 |
Event Date | Event Type | Old Value | New Value |
---|---|---|---|
2016-07-28 | Name Change | JMC Steel Group, Inc. | Zekelman Industries, Inc. |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339670564 | 0418600 | 2014-04-09 | 6340 AL HIGHWAY 5, THOMASVILLE, AL, 36762 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 5A0001 |
Issuance Date | 2014-08-04 |
Abatement Due Date | 2014-08-14 |
Current Penalty | 0.0 |
Initial Penalty | 3375.0 |
Final Order | 2014-09-04 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to burns and other injuries related to accidental contact with hot surfaces: a) Casing Heat Treatment Lines: On or about April 9, 2014 and at times prior thereto, the employer did not ensure guarding or another equivalent method was provided to prevent accidental contact with the steel pipes being heated up to 1670 degrees Fahrenheit. |
Citation ID | 01002 |
Citaton Type | Other |
Standard Cited | 19100219 F03 |
Issuance Date | 2014-08-04 |
Current Penalty | 7000.0 |
Initial Penalty | 2869.0 |
Final Order | 2014-09-04 |
Nr Instances | 2 |
Nr Exposed | 3 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: b) CNC 3 Waste: On or about April 9, 2014 and at times prior thereto, the employer did not ensure machine guarding or another effective method was used which exposed employees to amputations and other injuries associated with ingoing nip points.. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19100303 B06 |
Issuance Date | 2014-08-04 |
Current Penalty | 1721.0 |
Initial Penalty | 1721.0 |
Final Order | 2014-09-04 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(b)(6): Conductors located in wet or damp locations were not identified for that environment: a) Between Tubing Quench and MCC Room: On or about April 9, 2014 and at times prior thereto, the employer did not ensure a 2 receptacle outlet had ground fault circuit interrupter (GFCI) protection which exposed employees to electric shock hazards. |
Inspection Type | FollowUp |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2012-11-05 |
Emphasis | L: HINOISE |
Case Closed | 2012-11-20 |
Related Activity
Type | Inspection |
Activity Nr | 556418 |
Health | Yes |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Health |
Close Conference | 2012-07-20 |
Case Closed | 2012-12-14 |
Related Activity
Type | Complaint |
Activity Nr | 441092 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Other |
Standard Cited | 19100095 L01 |
Issuance Date | 2012-09-21 |
Abatement Due Date | 2012-09-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2012-10-19 |
Nr Instances | 1 |
Nr Exposed | 150 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.95(l)(1): The employer did not post of copy of 29 CFR 1910.95 in the workplace. (a) Facility: On or about July 18, 2012; the employer failed to post a copy of the hearing conservation standard where employees exposed over the 85dBa action level have ready access to it. |
Date of last update: 30 Jul 2024
Sources: Alabama Secretary of State