Search icon

Russell Lands, Incorporated

Details

Name: Russell Lands, Incorporated
Jurisdiction: Alabama
Legal type: Domestic Corporation
Status: Exists
Date of registration: 24 Sep 1962 (62 years ago)
Entity Number: 000-016-007
Register Number: 000016007
Place of Formation: Tallapoosa County
Registered Office Street Address: 2544 WILLOW POINT RDALEXANDER CITY, AL 35010-6219
Authorized Capital: $1,000
Paid Share Capital: $1,000

Activities DEAL IN REAL ESTATE

Commercial and government entity program

CAGE number Status Type Established CAGE Update Date CAGE Expiration SAM Expiration
44UK9 Obsolete Non-Manufacturer 2005-09-16 2022-02-15 2022-02-14 No data

Contact Information

POC NANCY JOHNSON
Phone +1 334-365-6100
Fax +1 334-365-6173
Address 2544 WILLOW POINT RD, ALEXANDER CITY, AL, 35010 6218, UNITED STATES

Ownership of Offeror Information

Highest Level Owner Information not Available
Immediate Level Owner Information not Available
List of Offerors (0) Information not Available

Incorporator

Name Role
RUSSELL, ROBERT A Incorporator
ALISON, ELIZABETH R Incorporator
RUSSELL, THOMAS D Incorporator

Agent

Name Role Address
FOREHAND, STEVE R Agent 2544 WILLOW POINT ROADALEXANDER CITY, AL 35010

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345926877 0418600 2022-04-27 1750 ALABAMA 22 W, ALEXANDER CITY, AL, 35010
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2022-04-27
Emphasis L: FALL
Case Closed 2022-08-12

Related Activity

Type Referral
Activity Nr 1886714
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100029 B02 I
Issuance Date 2022-07-08
Current Penalty 3804.0
Initial Penalty 6340.0
Final Order 2022-08-03
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.29(b)(2)(i): The employer did not ensure that guardrails met the requirement that midrails that are installed at a height midway between the top edge of the guardrail system and the walking-working surface. a) Insulation warehouse, Loft; On or about April 20, 2022 and at times prior to the employer exposed employees to fall hazards of 8 feet in that employees were allowed to access a loft area where rolls of insulation were stored that utilized a guardrail at the unprotected edge that did not have a mid-rail.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100029 B03
Issuance Date 2022-07-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-08-03
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.29(b)(3): The employer did not ensure that guardrail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in a downward or outward direction within 2 inches (5 cm) of the top edge, at any point along the top rail. a) Insulation warehouse, Loft; On or about April 20, 2022 and at times prior to the employer exposed employees to fall hazards of 8 feet in that employees were allowed to access a loft area where rolls of insulation were stored that utilized a guardrail at the unprotected edge that was damaged and not capable of withstanding the force of at least 200 pounds.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100028 B11 II
Issuance Date 2022-07-08
Abatement Due Date 2022-07-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2022-08-03
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.28(b)(11)(ii): 29 CFR 1910.28(b)(11)(ii): The employer did not ensure that each flight of stairs having at least 3 treads and at least 4 risers is equipped with stair rail systems and handrails as described in 29 CFR 1910.28 Table D-2-Stairway Handrail Requirements. a) Insulation loft, rear stair access; On or about April 28, 2022 and at times prior to the employer exposed employees to fall hazards of 8 feet in that employees were allowed to walk up and down fixed stairs with four or more risers that did not have a standard stair railing which included a mid-rail.
339816290 0418600 2014-06-17 2544 WILLOW POINT ROAD, ALEXANDER CITY, AL, 35010
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-06-17
Emphasis N: AMPUTATE
Case Closed 2014-08-28

Related Activity

Type Complaint
Activity Nr 893926
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100106 D04 I
Issuance Date 2014-07-21
Abatement Due Date 2014-07-31
Current Penalty 2500.0
Initial Penalty 4000.0
Final Order 2014-08-20
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.106(d)(4)(i): Opening(s) from inside flammable and combustible storage room(s) into other rooms or buildings were not provided with noncombustible liquid tight raised seal or ramp at least 4 inches in height. Opening(s) from inside flammable and combustible storage room(s) were not provided with approved self-closing fire doors. The inside flammable and combustible storage room(s) were not liquid-tight where the walls joined the floor: a) Carpenter Shop; On or about June 17, 2014 and at times prior thereto the employer exposed employees to fire hazards in that flammable liquids were stored inside a store room that did not meet the design requirements for a an inside flammable and combustible storage room. The storage room did not have a raised seal or ramp, self-closing fire doors, and was not liquid tight.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100304 G05
Issuance Date 2014-07-21
Abatement Due Date 2014-07-29
Current Penalty 2500.0
Initial Penalty 4000.0
Final Order 2014-08-20
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Carpenter Shop; On or about June 17, 2014 and at times prior thereto the employer exposed employees to electrical shock hazards in that the ground pin was missing on the male 220 vac power plug on the Grizzly 8" jointer.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100305 B01 II
Issuance Date 2014-07-21
Abatement Due Date 2014-07-29
Current Penalty 1600.0
Initial Penalty 3000.0
Final Order 2014-08-20
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Carpenter Shop; On or about June 16, 2014 and at times prior thereto the employer exposed employees to electrical and fire hazards in that employees were allowed to operate the sign machine which had an outlet box with an open hole not effectively closed.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2014-07-21
Abatement Due Date 2014-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-20
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Carpenter Shop; On or about June 17, 2014 and at times prior thereto the employer exposed employees to hazardous chemicals and substances that include but are not limited to paint, glue, paint thinner, lacquer, and wood stain without providing information and training on these chemicals and substances as required by the standard.
Citation ID 02002
Citaton Type Other
Standard Cited 19101200 H03 IV
Issuance Date 2014-07-21
Abatement Due Date 2014-07-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-20
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: a) Carpenter Shop; On or about June 17, 2014 and at times prior thereto the employer exposed employees to chemical hazards in that employees were not provided the new information and training on the UN Global Harmonized System (GHS) to include Safety Data Sheets (SDS).

Date of last update: 30 Jul 2024

Sources: Alabama Secretary of State