Search icon

MLC Framing LLC

Details

Name: MLC Framing LLC
Jurisdiction: Alabama
Legal type: Domestic Limited Liability Company
Status: Exists
Date of registration: 14 Jan 2011 (14 years ago)
Entity Number: 000-000-547
Register Number: 000000547
ZIP code: 35805
County: Madison
Place of Formation: Madison County
Registered Office Street Address: 2015 1ST STREETHUNTSVILLE, AL 35805

Activities FRAMING CONSTRUCTION

Agent

Name Role Address
BOATMAN, MISTY D Agent 2015 1ST STREETHUNTSVILLE, AL 35805

Member

Name Role Address
BOATMAN, MISTY D Member 2015 1ST STREETHUNTSVILLE, AL 35805

Organizer

Name Role Address
BOATMAN, MISTY D Organizer 2015 1ST STREETHUNTSVILLE, AL 35805

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342161387 0418300 2017-03-09 113 BAKERS FARM WAY, MADISON, AL, 35756
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2017-03-09
Emphasis L: FALL, P: FALL
Case Closed 2017-09-08

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2017-03-15
Current Penalty 1500.0
Initial Penalty 2355.0
Final Order 2017-03-29
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) On or about 03/09/2017 - 113 Bakers Farm Way in Madison, AL, employees operating a nail gun to install 2" X 6" roof rafters were not provided safety glasses.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2017-03-15
Current Penalty 2000.0
Initial Penalty 3803.0
Final Order 2017-03-29
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about 03/09/2017 - 113 Bakers Farm Way, Madison, AL, an employee installing roof rafters was standing on a single 2"x 6" board approximately 13-ft above the ground. b) On or about 03/09/2017 - 113 Bakers Farm Way, Madison, AL, an employee installing 2" x 6" roof rafters was standing approximately 14-ft above the ground.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2017-03-15
Abatement Due Date 2017-03-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-03-29
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) On or about 03/09/2017 - 113 Bakers Farm Way, Madison, AL, employees working from a single 2" x 6" board at approximately 13-ft above the ground were unaware of the fall hazards. b) On or about 03/09/2017 - 113 Bakers Farm Way, Madison, AL, employees working from an erected scaffolding system designed from 2" x 6" boards at approximately 14-ft above the ground were unaware of the fall hazards.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2017-03-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-03-29
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide: a) On or about 03/09/2017 - 113 Bakers Farm Way, Madison, AL, employees were working from a 2" X 6" board. b) On or about 03/09/2017 - 113 Bakers Farm Way, Madison, AL, employees working from a scaffold system at 14-ft above the ground did not have the scaffold fully planked.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2017-03-15
Current Penalty 1000.0
Initial Penalty 1177.0
Final Order 2017-03-29
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access and the ladder was not secured at the top: a) On or about 03/19/2017 - 113 Bakers Farm Way, Madison, AL, employees gaining access to the second floor did not have a suitable ladder.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2017-03-15
Abatement Due Date 2017-03-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-03-29
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: a) On or about 03/09/2017 - 113 Bakers Farm Way, Madison, AL, employees using a ladder that did not extend 3-ft above the landing surface were unaware of the hazards. b) On or about 03/09/2017 - 113 Bakers Farm Way, Madison, AL, employees installed the moisture barrier to the external walls of the residential home using a defective ladder.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B16
Issuance Date 2017-03-15
Current Penalty 1500.0
Initial Penalty 2770.0
Final Order 2017-03-29
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: a) On or about 03/09/2017 - 113 Bakers Farm Way, Madison, AL, employees used a section of an extension ladder that had bends in the rungs.

Date of last update: 29 Jul 2024

Sources: Alabama Secretary of State